W DOC AIRBUS | TSM A320F

Loss of the Reception of the DME 1 Bus by one FMGC


TASK 22-83-00-810-839-A
Loss of the Reception of the DME 1 Bus by one FMGC


1. Possible Causes
  • FMGC-1 [1CA1]
  • INTRG-DME, 1 [2SD1]
  • wiring of the DME OWN bus from the FMGC 1 (1CA1) to the DME interrogator 1 (2SD1)
  • FMGC-2 [1CA2]
  • wiring of the DME OPP bus from the FMGC 2 (1CA2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228601
AMM 22-91-00-710-001
Ground Scanning of the AFS
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 22-83-00-865-066-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV/DME/11SD1G14
Subtask 22-83-00-710-110-A
B. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
4. Fault Isolation
Subtask 22-83-00-810-106-A
A. If the test gives the maintenance message AFS : DME1 (ISSUED BY : FM1):
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the DME OWN bus from the FMGC 1 (1CA1) to the DME interrogator 1 (2SD1) ASM 228601.
Subtask 22-83-00-810-107-A
B. If the test gives the maintenance message AFS : DME1 (ISSUED BY : FM2):
   (1) If the fault continues:
  • do a check and repair the wiring of the DME OPP bus from the FMGC 2 (1CA2) to the first terminal block ASM 228601.
Subtask 22-83-00-710-111-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:31 UTC