W DOC AIRBUS | TSM A320F

Automatic Transfer of the FD 2 Indication to the PFD 1 Inoperative


TASK 22-83-00-810-831-A
Automatic Transfer of the FD 2 Indication to the PFD 1 Inoperative


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FD OWN ENGD MON OPP discrete (from the FMGC 2 (1CA2) to the first terminal block)
  • DMC-1 [1WT1]
  • wiring of the FD 2 ENGD from the DMC 1 (1WT1) to the first terminal block
  • FMGC-1 [1CA1]
  • wiring of the FD OPP ENGD MON discrete (from the FMGC 1 (1CA1) to the first terminal block)
  • wiring of the FD OPP ENGD COM discrete (from the FMGC 1 (1CA1) to the FMGC 2 (1CA2))
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228502
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 22-83-00-865-060-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAUTO FLT/FCU/19CA1B05
49VUAUTO FLT/FMGC/110CA1B02
121VUAUTO FLT/FCU/29CA2M21
121VUAUTO FLT/FMGC/210CA2M17
Subtask 22-83-00-860-050-A
B. Aircraft Maintenance Configuration
   (1) Do the EIS start procedure AMM 31-60-00-860-001.
   (2) Make sure that the two FDs are engaged (if they are not engaged, push the FD pushbutton switches on the FCU).
Subtask 22-83-00-710-098-B
C. Test
   (1) Open the circuit breaker 10CA1 and make sure that the FD 2 indication comes into view on the PFD 1.
   (2) Close the circuit breaker 10CA1.
   (3) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1.
4. Fault Isolation
Subtask 22-83-00-810-090-B
A. If the FD 2 indication does not come into view on the PFD 1 and if the test gives the maintenance message AFS: FMGC1/FMGC2 (FD CKT):
   (1) If the fault continues:
  • do a check and repair the wiring of the FD OWN ENGD MON OPP discrete (from the FMGC 2 (1CA2) to the first terminal block), ASM 228502.
Subtask 22-83-00-810-091-A
B. If the FD 2 indication does not come into view on the PFD 1 and if no messages come into view after the test:
   (1) If the fault continues:
  • do a check and repair the wiring of the FD 2 ENGD from the DMC 1 (1WT1) to the first terminal block, ASM 228502.
Subtask 22-83-00-810-092-A
C. If the FD 2 indication comes into view on the PFD 1 and if the test gives the maintenance message AFS: FMGC1/FMGC2 (FD CKT):
   (1) If the fault continues:
  • do a check of the wiring of the FD OPP ENGD MON discrete (from the FMGC 1 (1CA1) to the first terminal block), ASM 228502.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the FD OPP ENGD COM discrete (from the FMGC 1 (1CA1) to the FMGC 2 (1CA2)), ASM 228502.
Subtask 22-83-00-710-099-A
D. Do the test given in Para. 3.
5. Close-up
Subtask 22-83-00-860-051-B
A. Put the aircraft back to its initial configuration.
   (1) Close the circuit breaker 10CA1.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.