Loss of the Reception of the FMGC 1 OWN A Bus by the FMGC 2
TASK 22-83-00-810-815-A
Loss of the Reception of the FMGC 1 OWN A Bus by the FMGC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-070-A
Subtask 22-83-00-810-068-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:30 UTC
Loss of the Reception of the FMGC 1 OWN A Bus by the FMGC 2
1. Possible Causes
- FMGC-2 [1CA2]
wiring of the FMGC OPP A (COM) and FMGC OPP A (MON) buses (from the FMGC 2 (1CA2) to the first terminal block) wiring of the FMGC OPP HLTY discrete (from the FMGC 2 (1CA2) to the first termi al block)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228504 | |
| ASM 228602 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-83-00-710-070-A
A. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
Subtask 22-83-00-810-068-A
A. If the test gives the maintenance message AFS: FMGC2/FMGC1 BUS A WG:
Subtask 22-83-00-710-071-A - replace the FMGC-2 [1CA2] , AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check of the
wiring of the FMGC OPP A (COM) and FMGC OPP A (MON) buses (from the FMGC 2 (1CA2) to the first terminal block) ASM 228602.
- repair the above wiring.
- do a check and repair the
wiring of the FMGC OPP HLTY discrete (from the FMGC 2 (1CA2) to the first termi al block) ASM 228504.
B. Do the test given in Para. 3.