Loss of the FMGC 2 OWN CB1 Bus (RMP 2 Source)


TASK 22-83-00-810-813-A
Loss of the FMGC 2 OWN CB1 Bus (RMP 2 Source)


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FMGC OWN CB 1 (COM) bus (from the FMGC 2 (1CA2) to the first terminal block)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
AMM 23-13-00-740-001
BITE Test of the Radio Management
3. Fault Confirmation
Subtask 22-83-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/FMGC/210CA2M17
Subtask 22-83-00-740-058-A
B. Test
   (1) Do the BITE test of the radio management AMM 23-13-00-740-001 and read the result for the RMP 2.
4. Fault Isolation
Subtask 22-83-00-810-066-B
A. If the test gives the maintenance message FMGC2(1CA2)/RMP2(1RG2):
   (1) If the fault continues:
  • do a check and repair the wiring of the FMGC OWN CB 1 (COM) bus (from the FMGC 2 (1CA2) to the first terminal block) ASM 228602.
Subtask 22-83-00-740-059-A
B. Do the test given in Para. 3.