Loss of the AP INST DISC Discretes on the FMGC 1


TASK 22-83-00-810-807-A
Loss of the AP INST DISC Discretes on the FMGC 1


1. Possible Causes
  • FMGC-1 [1CA1]
  • wiring of the AP INST DISC NO discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1)
  • wiring of the GND FILTERED discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1))
  • RELAY-TAKEOVER & PRIORITY 1 [47CE1]
  • wiring of the AP INST DISC NC discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1))
  • wiring of the takeover and priority relay (47CE1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228503
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-83-00-710-062-A
A. Test
   (1) On the FCU, make sure that the two AP pushbutton switches are pushed.
   (2) Do the operational tests of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1:
     (a) With one takeover and priority pushbutton switch pushed (on side stick).
     (b) With the two takeover and priority pushbutton switches released.
4. Fault Isolation
Subtask 22-83-00-810-056-B
A. If only the first test gives the maintenance message AFS: FMGC1/TAKE OV CKT:
   (1) If the fault continues:
  • do a check of the wiring of the AP INST DISC NO discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1) ASM 228503.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check of the wiring of the GND FILTERED discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1)) ASM 228503.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • replace the RELAY-TAKEOVER & PRIORITY 1 [47CE1] .
Subtask 22-83-00-810-057-B
B. If only the second test gives the maintenance message AFS: FMGC1/TAKE OV CKT:
   (1) If the fault continues:
  • do a check of the wiring of the AP INST DISC NC discrete (from the FMGC 1 (1CA1) to the takeover and priority relay (47CE1)) ASM 228503.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check of the wiring of the takeover and priority relay (47CE1) (from 47CE1 pin A/D to the first terminal block) ASM 228503.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • replace the RELAY-TAKEOVER & PRIORITY 1 [47CE1] .
Subtask 22-83-00-710-063-A
C. Do the tests given in Para. 3.