W DOC AIRBUS | TSM A320F

AP 2 Engagement Inoperative


TASK 22-83-00-810-806-A
AP 2 Engagement Inoperative


1. Possible Causes
  • FMGC-2 [1CA2]
  • FCU [2CA]
  • wiring of the CMD 2 SW COM and CMD 2 SW MON discretes (from the FCU (2CA) to the FMGC 2 (1CA2))
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-81-12-000-001
Removal of the FCU
AMM 22-81-12-400-001
Installation of the FCU
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228503
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-83-00-710-060-A
A. Test
   (1) On the FCU, push the AP 2 pushbutton switch.
   (2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
4. Fault Isolation
Subtask 22-83-00-810-055-A
A. If the test gives the maintenance message AFS : FMGC2/FCU (AP2 SW):
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring of the CMD 2 SW COM and CMD 2 SW MON discretes (from the FCU (2CA) to the FMGC 2 (1CA2)) ASM 228503.
Subtask 22-83-00-710-061-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:29 UTC