AP 1 Engagement Inoperative
TASK 22-83-00-810-805-A
AP 1 Engagement Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-058-A
Subtask 22-83-00-810-054-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:29 UTC
AP 1 Engagement Inoperative
1. Possible Causes
- FMGC-1 [1CA1]
- FCU [2CA]
wiring of the CMD 1 SW COM and CMD 1 SW MON discretes (from the FCU (2CA) to the FMGC 1 (1CA1))
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228503 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-83-00-710-058-A
A. Test
(1) On the FCU, push the AP 1 pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1.
4. Fault Isolation(1) On the FCU, push the AP 1 pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1.
Subtask 22-83-00-810-054-A
A. If the test gives the maintenance message AFS : FMGC1/FCU (AP1 SW):
Subtask 22-83-00-710-059-A - replace the FMGC-1 [1CA1] , AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the FCU [2CA] , AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
- do a check and repair the
wiring of the CMD 1 SW COM and CMD 1 SW MON discretes (from the FCU (2CA) to the FMGC 1 (1CA1)) ASM 228503.
B. Do the test given in Para. 3.