W DOC AIRBUS | TSM A320F

Loss of Communication with the Data Link through the MCDU 2


TASK 22-82-00-810-820-A
Loss of Communication with the Data Link through the MCDU 2


1. Possible Causes
  • MCDU-2 [3CA2]
  • wiring of the ATSU-1 RECEIVER bus from the MCDU 2 (3CA2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-82-12-000-001
Removal of the MCDU
AMM 22-82-12-400-002
Installation of the MCDU
ASM 228604
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
3. Fault Confirmation
Subtask 22-82-00-860-060-A
A. Job Set-up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Make sure that the ventilation of the electronics racks is in operation.
Subtask 22-82-00-710-088-C
B. Test
ACTION
RESULT
1.On the center pedestal, on the MCDU 2:
On the center pedestal, on the MCDU 2:
  • push the MCDU MENU mode key.
The MCDU MENU page comes into view.
  • push the line key adjacent to the ATSU indication.
The ATSU DATALINK page comes into view.
4. Fault Isolation
Subtask 22-82-00-810-077-C
A. If the ATSU DATALINK page does not come into view:
   (1) If the fault continues:
  • do a check and repair the wiring of the ATSU-1 RECEIVER bus from the MCDU 2 (3CA2) to the first terminal block ASM 228604.
Subtask 22-82-00-710-089-A
B. Do the test given in Para. 3.C.
5. Close-up
Subtask 22-82-00-860-061-A
A. Put the aircraft back to its initial configuration.
   (1) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.