Automatic Switching of the MCDU 1 Inoperative
TASK 22-82-00-810-813-A
Automatic Switching of the MCDU 1 Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-82-00-710-074-A 4. Fault Isolation
Subtask 22-82-00-810-070-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:27 UTC
Automatic Switching of the MCDU 1 Inoperative
1. Possible Causes
- FMGC-2 [1CA2]
- MCDU-1 [3CA1]
wiring of the MCDU OPP OUT bus from the FMGC 2 (1CA2) to the MCDU 1 (3CA1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-70-00-710-003 | Operational Test of the Automatic Switching of the MCDUs |
| AMM 22-82-12-000-001 | Removal of the MCDU |
| AMM 22-82-12-400-002 | Installation of the MCDU |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228604 |
Subtask 22-82-00-710-074-A 4. Fault Isolation
Subtask 22-82-00-810-070-A
A. If the INIT page does not come into view on the MCDU 1 when the FMGC 1 is deactivated:
Subtask 22-82-00-710-075-A - replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the MCDU-1 [3CA1] AMM 22-82-12-000-001 and AMM 22-82-12-400-002.
- do a check and repair the
wiring of the MCDU OPP OUT bus from the FMGC 2 (1CA2) to the MCDU 1 (3CA1) ASM 228604.
B. Do the test given in Para. 3.