Loss of Power Supply 26VAC of the Position Feedback Transducers Side 2


TASK 22-61-00-810-808-A
Loss of Power Supply 26VAC of the Position Feedback Transducers Side 2


1. Possible Causes
  • wiring of the 26VAC signal from the circuit breaker 14CC2 to the first terminal block
  • C/B-AUTO FLT/FAC2/26VAC [14CC2]
  • LIMITATION UNIT-RUDDER TRAVEL [4CC]
  • ACTUATOR-RUDDER TRIM [10CC]
  • SERVO ACTR-YAW DAMPER, 2 [3CC2]
  • XDCR UNIT-YAW DAMPER POS [2CC]
  • short to ground between the circuit breaker 14CC2 and the four units
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226701
AMM 22-91-00-710-001
Ground Scanning of the AFS
AMM 27-22-51-000-001
Removal of the Rudder Trim Actuator
AMM 27-22-51-400-001
Installation of the Rudder Trim Actuator
AMM 27-23-51-000-001
Removal of the Rudder Travel Limitation Unit
AMM 27-23-51-400-001
Installation of the Rudder Travel-Limitation Unit
AMM 27-26-17-000-001
Removal of the Yaw Damper Position Transducer Unit
AMM 27-26-17-400-001
Installation of the Yaw Damper Position Transducer Unit
AMM 27-26-51-000-001
Removal of the Yaw Damper Servo Actuator
AMM 27-26-51-400-001
Installation of the Yaw Damper Servo Actuator
3. Fault Confirmation
Subtask 22-61-00-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/FAC2/26VAC14CC2M18
Subtask 22-61-00-710-066-A
B. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
     (a) If the circuit breaker 14CC2 is open, refer to Para. 4.B.
4. Fault Isolation
Subtask 22-61-00-810-059-A
A. If the circuit breaker 14CC2 is closed, and if the test gives the maintenance message AFS: 231 XPA BUS BAR:
  • do a check of the wiring of the 26VAC signal from the circuit breaker 14CC2 to the first terminal block , ASM 226701.
   (1) If there is no continuity:
  • repair the above wiring.
   (2) If there is continuity:
  • replace the C/B-AUTO FLT/FAC2/26VAC [14CC2] .
Subtask 22-61-00-810-061-A
B. If the circuit breaker 14CC2 is open:
  • close this circuit breaker.
   (1) If this circuit breaker opens again:
  • disconnect these four units:
    LIMITATION UNIT-RUDDER TRAVEL [4CC]
    ACTUATOR-RUDDER TRIM [10CC]
    SERVO ACTR-YAW DAMPER, 2 [3CC2]
    XDCR UNIT-YAW DAMPER POS [2CC]
  • close the circuit breaker 14CC2.
     (a) If this circuit breaker stays closed:
     (b) If this circuit breaker opens again:
  • do a check for a short to ground between the circuit breaker 14CC2 and the four units , ASM 226701.
       1 If there is a short to ground:
  • repair the related wiring.
       2 If there is no short to ground:
  • replace the C/B-AUTO FLT/FAC2/26VAC [14CC2] .
   (2) Connect all the units.
Subtask 22-61-00-710-067-A
C. Do the test given in Para. 3.