W DOC AIRBUS | TSM A320F

Loss of the Power Supply 26VAC of the Rudder Travel Limiting Side 2


TASK 22-61-00-810-806-A
Loss of the Power Supply 26VAC of the Rudder Travel Limiting Side 2


1. Possible Causes
  • electronic module
  • LIMITATION UNIT-RUDDER TRAVEL [4CC]
  • wiring of the 26VAC signal at the rudder travel-limitation unit (4CC)
  • wiring of the ground signal at the rudder travel-limitation unit (4CC)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226701
AMM 22-91-00-710-001
Ground Scanning of the AFS
AMM 27-23-51-000-001
Removal of the Rudder Travel Limitation Unit
AMM 27-23-51-000-002
Removal of the Electronic Module of the Rudder Travel Limitation Unit
AMM 27-23-51-400-001
Installation of the Rudder Travel-Limitation Unit
AMM 27-23-51-400-002
Installation of the Electronic Module of the Rudder Travel Limitation Unit
3. Fault Confirmation
Subtask 22-61-00-710-062-A
A. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
4. Fault Isolation
Subtask 22-61-00-810-057-A
A. If the test gives the maintenance message AFS : 231 XPA BUS BAR:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check of the wiring of the 26VAC signal at the rudder travel-limitation unit (4CC) from pin B/K to the first terminal block ASM 226701.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the ground signal at the rudder travel-limitation unit (4CC) pin B/V ASM 226701.
Subtask 22-61-00-710-063-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:11 UTC