Loss of the Power Supply 26VAC of the Rudder Travel Limiting Side 1
TASK 22-61-00-810-805-A
Loss of the Power Supply 26VAC of the Rudder Travel Limiting Side 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-61-00-710-060-A 4. Fault Isolation
Subtask 22-61-00-810-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:11 UTC
Loss of the Power Supply 26VAC of the Rudder Travel Limiting Side 1
1. Possible Causes
- electronic module
- LIMITATION UNIT-RUDDER TRAVEL [4CC]
wiring of the 26VAC signal at the rudder travel-limitation unit (4CC) wiring of the ground signal at rudder travel-limitation unit (4CC)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 226701 | |
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 27-23-51-000-001 | Removal of the Rudder Travel Limitation Unit |
| AMM 27-23-51-000-002 | Removal of the Electronic Module of the Rudder Travel Limitation Unit |
| AMM 27-23-51-400-001 | Installation of the Rudder Travel-Limitation Unit |
| AMM 27-23-51-400-002 | Installation of the Electronic Module of the Rudder Travel Limitation Unit |
Subtask 22-61-00-710-060-A 4. Fault Isolation
Subtask 22-61-00-810-056-A
A. If the test gives the maintenance message AFS : 431 XPA BUS BAR:
Subtask 22-61-00-710-061-A - replace the electronic module of the rudder travel-limitation unit (4CC) AMM 27-23-51-000-002 and AMM 27-23-51-400-002.
- replace the LIMITATION UNIT-RUDDER TRAVEL [4CC] , AMM 27-23-51-000-001 and AMM 27-23-51-400-001.
- do a check of the
wiring of the 26VAC signal at the rudder travel-limitation unit (4CC) from pin A/K to the first terminal block ASM 226701.
- repair the above wiring.
- do a check and repair the
wiring of the ground signal at rudder travel-limitation unit (4CC) pin A/V ASM 226701.
B. Do the test given in Para. 3.