Loss of the Reception of the RTL ENGD Discrete Feedback by the FAC 2
TASK 22-61-00-810-802-A
Loss of the Reception of the RTL ENGD Discrete Feedback by the FAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-61-00-710-052-A
Subtask 22-61-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:09 UTC
Loss of the Reception of the RTL ENGD Discrete Feedback by the FAC 2
1. Possible Causes
- FAC-2 [1CC2]
wiring of the RTL ENGD COM and RTL ENGD MON discretes from the FAC 2 (1CC2) to the first terminal block wiring of the RTL OWN ENGD COM and RTL OWN ENGD MON discretes from the FAC 2 (1CC2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-60-00-710-002 | Operational Test of the Automatic Change-Over Function |
| AMM 22-66-34-000-002 | Removal of the FAC |
| AMM 22-66-34-400-002 | Installation of the FAC |
| ASM 226802 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-61-00-710-052-A
A. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
(2) Do the operational test of the automatic change-over function AMM 22-60-00-710-002.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
(2) Do the operational test of the automatic change-over function AMM 22-60-00-710-002.
Subtask 22-61-00-810-051-A
A. If the operational test of the AFS gives the maintenance message AFS: FAC 2/RTL ENGD FDBK:
(1) If the operational test of the automatic change-over function gives the maintenance message AFS: FAC 1/RTL ENGD CHG-OV:
Subtask 22-61-00-710-053-A (1) If the operational test of the automatic change-over function gives the maintenance message AFS: FAC 1/RTL ENGD CHG-OV:
- replace the FAC-2 [1CC2] , AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the RTL ENGD COM and RTL ENGD MON discretes from the FAC 2 (1CC2) to the first terminal block ASM 226802.
- replace the FAC 2 (1CC2) AMM 22-66-34-000-002 and AMM 22-66-34-400-002.
- do a check and repair the
wiring of the RTL OWN ENGD COM and RTL OWN ENGD MON discretes from the FAC 2 (1CC2) to the first terminal block ASM 226802.
B. Do the operational test given in Para. 3.A.(1).