Disagree between the A/THR ENGD Discretes (FMGC1 and FMGC2)
TASK 22-31-00-810-814-A
Disagree between the A/THR ENGD Discretes (FMGC1 and FMGC2)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-31-00-710-076-A
Subtask 22-31-00-810-069-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:09 UTC
Disagree between the A/THR ENGD Discretes (FMGC1 and FMGC2)
1. Possible Causes
- FMGC-1 [1CA1]
- FMGC-2 [1CA2]
wiring of the ATH OWN ENGD (COM and MON) OPP and ATH OPP ENGD (COM and MON) OPP discretes between the FMGC1 and the FMGC2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 223101 | |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-31-00-710-076-A
A. Test
(1) On the FCU, push the A/THR pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the results for the FMGC1 and for the FMGC2.
4. Fault Isolation(1) On the FCU, push the A/THR pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the results for the FMGC1 and for the FMGC2.
Subtask 22-31-00-810-069-A
A. If the test gives the maintenance messages AFS: FMGC2/ATHR ENGD FDBK for the FMGC2 and AFS: FMGC1/ATHR2 ENG WIRG for the FMGC1:
Subtask 22-31-00-710-077-A - remove the FMGC-1 [1CA1] AMM 22-83-34-000-001
- do the operational test of the AFS AMM 22-96-00-710-001.
- replace the FMGC-2 [1CA2] AMM 22-83-34-400-001
- replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 AMM 22-83-34-400-001.
- do a check and repair of the
wiring of the ATH OWN ENGD (COM and MON) OPP and ATH OPP ENGD (COM and MON) OPP discretes between the FMGC1 and the FMGC2 ASM 223101.
B. Do the test given in Para. 3.