W DOC AIRBUS | TSM A320F

Disagree between the A/THR ENGD Discretes (FMGC1 and FMGC2)


TASK 22-31-00-810-813-A
Disagree between the A/THR ENGD Discretes (FMGC1 and FMGC2)


1. Possible Causes
  • FMGC-2 [1CA2]
  • FMGC-1 [1CA1]
  • wiring of the ATH OWN ENGD (COM and MON) OPP and ATH OPP ENGD (COM and MON) OPP discretes between the FMGC1 and the FMGC2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 223101
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-31-00-710-074-A
A. Test
   (1) On the FCU, push the A/THR pushbutton switch.
   (2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the results of the FMGC1 and the FMGC2.
4. Fault Isolation
Subtask 22-31-00-810-068-A
A. If the test gives the maintenance messages AFS: FMGC1/ATHR ENGD FDBK for the FMGC1 and AFS: FMGC2/ATHR1 ENG WIRG for the FMGC2:
   (1) If the test gives the message: AFS TEST OK
   (2) If the the test result of the FMGC1 gives the maintenance message AFS: FMGC1/ATHR ENGD FDBK:
   (3) If the fault continues:
  • do a check and repair of the wiring of the ATH OWN ENGD (COM and MON) OPP and ATH OPP ENGD (COM and MON) OPP discretes between the FMGC1 and the FMGC2 ASM 223101.
Subtask 22-31-00-710-075-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:09 UTC