Unwanted A/THR 1 and 2 Inoperative Warning
TASK 22-31-00-810-812-A
Unwanted A/THR 1 and 2 Inoperative Warning
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-31-00-710-072-A
Subtask 22-31-00-810-067-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:09 UTC
Unwanted A/THR 1 and 2 Inoperative Warning
1. Possible Causes
- RELAY-A/THR1 CMD ENGAGED [17CA1]
- RELAY-A/THR1 MON ENGAGED [18CA1]
- RELAY-A/THR2 CMD ENGAGED [17CA2]
- RELAY-A/THR2 MON ENGAGED [18CA2]
- RELAY-A/THR1 INST DISC [5CA1]
- RELAY-A/THR2 INST DISC [5CA2]
- P/BSW-A/THR INST DISC, CAPT [7CA1]
- P/BSW-A/THR INST DISC, F/O [7CA2]
DIODE MODULE (1803VD) wiring of the engines interface via the relays 5CA1, 5CA2, 17CA1, 17CA2, 18CA1, 18CA2,
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 223101 | |
| ASM 732512 |
Subtask 22-31-00-710-072-A
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationSubtask 22-31-00-810-067-A
A. Replace the relays RELAY-A/THR1 CMD ENGAGED [17CA1] and RELAY-A/THR1 MON ENGAGED [18CA1] ASM 223101.
(1) If the fault continues:
(1) If the fault continues:
- Replace the RELAY-A/THR2 CMD ENGAGED [17CA2] and RELAY-A/THR2 MON ENGAGED [18CA2] ASM 223101.
- Replace the relays RELAY-A/THR1 INST DISC [5CA1] and RELAY-A/THR2 INST DISC [5CA2] ASM 223101.
- Replace the P/BSW-A/THR INST DISC, CAPT [7CA1] and P/BSW-A/THR INST DISC, F/O [7CA2] ASM 223101.
- Replace the
DIODE MODULE (1803VD) ASM 223101.
- Do a check of the
wiring of the engines interface via the relays 5CA1, 5CA2, 17CA1, 17CA2, 18CA1, 18CA2, ASM 732512.