A/THR Engagement Inoperative on the FMGC 2
TASK 22-31-00-810-806-A
A/THR Engagement Inoperative on the FMGC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-31-00-710-060-A
Subtask 22-31-00-810-055-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:09 UTC
A/THR Engagement Inoperative on the FMGC 2
1. Possible Causes
- FMGC-2 [1CA2]
- FCU [2CA]
wiring of the A/THR 2 SW COM and A/THR 2 SW MON discretes (from the FCU (2CA) to the FMGC 2 (1CA2))
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 223101 | |
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-31-00-710-060-A
A. Test
(1) On the FCU, push the A/THR pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
4. Fault Isolation(1) On the FCU, push the A/THR pushbutton switch.
(2) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
Subtask 22-31-00-810-055-A
A. If the test gives the maintenance message AFS : FMGC2/FCU (ATHR SW):
Subtask 22-31-00-710-061-A - replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
- do a check and repair the
wiring of the A/THR 2 SW COM and A/THR 2 SW MON discretes (from the FCU (2CA) to the FMGC 2 (1CA2)) ASM 223101.
B. Do the test given in Para. 3.