Loss of FD Engagement in Crossed Bars at Go Around
TASK 22-11-00-810-836-A
Loss of FD Engagement in Crossed Bars at Go Around
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-710-105-A
Subtask 22-11-00-810-092-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:08 UTC
Loss of FD Engagement in Crossed Bars at Go Around
1. Possible Causes
wiring of the FD ENGAGEMENT IN CROSSED BARS AT GO AROUND signal (pin program) - FCU [2CA]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| ASM 228506 |
Subtask 22-11-00-710-105-A
A. Not applicable
4. Fault IsolationSubtask 22-11-00-810-092-A
A. Do a check and repair of the wiring of the FD ENGAGEMENT IN CROSSED BARS AT GO AROUND signal (pin program) on the FCU:
(1) remove the FCU [2CA] AMM 22-81-12-000-001:
Subtask 22-11-00-710-106-A (1) remove the FCU [2CA] AMM 22-81-12-000-001:
- check that Pins S respectively on the connectors A and B are grounded ASM 228506
- install the FCU AMM 22-81-12-400-001.
- replace the FCU [2CA] AMM 22-81-12-000-001 AMM 22-81-12-400-001.
B. Not applicable.