Loss of the FMGC 1 EIS COM Bus (Source EIS 2)
TASK 22-11-00-810-830-A
Loss of the FMGC 1 EIS COM Bus (Source EIS 2)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-865-063-A
Subtask 22-11-00-810-085-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:08 UTC
Loss of the FMGC 1 EIS COM Bus (Source EIS 2)
1. Possible Causes
- FMGC-1 [1CA1]
wiring of the EIS (COM) bus from the FMGC 1 (1CA1) to the first terminal block wiring of the FMGC HLTY discretes (from the FMGC 1 (1CA1) to the first terminal block)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228504 | |
| ASM 228602 | |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
Subtask 22-11-00-865-063-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-11-00-740-066-A ** ON A/C NOT FOR ALL Subtask 22-11-00-740-066-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AUTO FLT/FMGC/1 | 10CA1 | B02 |
Subtask 22-11-00-810-085-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : NO FMC 1 DATA:
Subtask 22-11-00-810-085-B ** ON A/C NOT FOR ALL - replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check of the
wiring of the EIS (COM) bus from the FMGC 1 (1CA1) to the first terminal block ASM 228602.
- repair the above wiring.
- do a check and repair the
wiring of the FMGC HLTY discretes (from the FMGC 1 (1CA1) to the first terminal block) ASM 228504.
A. If the test gives the maintenance message FMGC1(1CA1)BUS FM1 TO EIS/DMC2(1WT2)
Subtask 22-11-00-740-067-A - replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check of the
wiring of the EIS (COM) bus from the FMGC 1 (1CA1) to the first terminal block ASM 228602.
- repair the above wiring.
- do a check and repair the
wiring of the FMGC HLTY discretes (from the FMGC 1 (1CA1) to the first terminal block) ASM 228504.
B. Do the test given in Para. 3.