W DOC AIRBUS | TSM A320F

Loss of the AP Pushbutton Switch Function on the FMGC 2


TASK 22-11-00-810-828-A
Loss of the AP Pushbutton Switch Function on the FMGC 2


1. Possible Causes
  • FMGC 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 22-97-00-710-001
Operational Test of the LAND CAT III Capability
3. Fault Confirmation
Subtask 22-11-00-710-101-A
A. Test
   (1) Do the operational test of the LAND CAT III capability AMM 22-97-00-710-001.
4. Fault Isolation
Subtask 22-11-00-865-073-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/FCU/29CA2M21
121VUAUTO FLT/FMGC/210CA2M17
Subtask 22-11-00-810-083-A
B. If the test gives the maintenance message AFS: CHK FMGC2-AP P/B CKT:
  • open the circuit breakers 9CA2 and 10CA2
  • after 15 s, close these circuit breakers
  • push the AP 2 pushbutton switch
  • after 1 minute, do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2 .
    If the test gives a different message, do the trouble shooting procedure related to the maintenance message.
Subtask 22-11-00-710-102-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:08 UTC