Loss of the AP Pushbutton Switch Function on the FMGC 2
TASK 22-11-00-810-828-A
Loss of the AP Pushbutton Switch Function on the FMGC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-710-101-A 4. Fault Isolation
Subtask 22-11-00-865-073-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:08 UTC
Loss of the AP Pushbutton Switch Function on the FMGC 2
1. Possible Causes
- FMGC 2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-96-00-710-001 | Operational Test of the AFS |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
Subtask 22-11-00-710-101-A 4. Fault Isolation
Subtask 22-11-00-865-073-A
A. Table of the circuit breakers used in this procedure:
Subtask 22-11-00-810-083-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/FCU/2 | 9CA2 | M21 |
| 121VU | AUTO FLT/FMGC/2 | 10CA2 | M17 |
B. If the test gives the maintenance message AFS: CHK FMGC2-AP P/B CKT:
Subtask 22-11-00-710-102-A - open the circuit breakers 9CA2 and 10CA2
- after 15 s, close these circuit breakers
- push the AP 2 pushbutton switch
- after 1 minute, do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2 .
If the test gives a different message, do the trouble shooting procedure related to the maintenance message.