AP 2 Engagement Inoperative after the Installation of the New FMGC
TASK 22-11-00-810-826-A
AP 2 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-710-097-A
Subtask 22-11-00-810-080-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:07 UTC
AP 2 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 2 (1CA2) to the relay (47CE1))
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 228503 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-11-00-710-097-A
A. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
Subtask 22-11-00-810-080-B
A. If the test gives the maintenance message AFS: FMGC2/TAKE OV CKT:
Subtask 22-11-00-710-098-A - do a check and repair the
wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 2 (1CA2) to the relay (47CE1)) ASM 228503.
B. Do the test given in Para. 3.