AP 1 Engagement Inoperative after the Installation of the New FMGC
TASK 22-11-00-810-825-A
AP 1 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-710-095-A
Subtask 22-11-00-810-078-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:07 UTC
AP 1 Engagement Inoperative after the Installation of the New FMGC
1. Possible Causes
wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 1 (1CA1) to the relay (47CE1)) wiring of the AP OWN ENGD COM OPP discrete from the FMGC 1 (1CA1) wiring of the AP OWN ENGD COM OWN discrete from the FMGC 1 (1CA1) - FCU [2CA]
wiring of the CMD 1 SW COM discrete from the FCU (2CA) to the FMGC 1 (1CA1) wiring of the AP OWN ENGD MON OPP discrete from the FMGC 1 (1CA1) wiring of the AP OWN ENGD MON OWN discrete from the FMGC 1 (1CA1) wiring of the CMD 1 SW MON discrete from the FCU (2CA) to the FMGC 1 (1CA1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| ASM 228503 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-11-00-710-095-A
A. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 1.
Subtask 22-11-00-810-078-B
A. If the test gives the maintenance message AFS: FMGC1/TAKE OV CKT:
Subtask 22-11-00-810-079-A - do a check and repair the
wiring of the AP INST DISC NC and AP INST DISC NO discretes (from the FMGC 1 (1CA1) to the relay (47CE1)) ASM 228503.
B. If the test gives the message LRU TEST NOT COMPLETED:
Subtask 22-11-00-710-096-A - push the line key adjacent to the RETURN indication until the AFS MAIN MENU page comes into view
- push the line key adjacent to the TROUBLE SHOOTING DATA indication
- push the line key adjacent to the FG 1 COM indication, then FG 1 MON indication:
. make sure that there is a snapshot related to an event 1 at AFS TEST time. - on word 5, make sure that the fourth number is equal to:
. 8 or 9 or A or B or C or D or E or F (on the command and monitoring channels).
- do a check of the
wiring of the AP OWN ENGD COM OPP discrete from the FMGC 1 (1CA1) (from pin AA/14B to pin AB/3G) - do a check of the
wiring of the AP OWN ENGD COM OWN discrete from the FMGC 1 (1CA1) (from pin AB/10D to pin AB/3E)
ASM 228503.
- repair the above wiring.
- replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
- do a check and repair the
wiring of the CMD 1 SW COM discrete from the FCU (2CA) to the FMGC 1 (1CA1) ASM 228503.
- do a check of the
wiring of the AP OWN ENGD MON OPP discrete from the FMGC 1 (1CA1) (from pin AD/14D to pin AE/3G) - do a check of the
wiring of the AP OWN ENGD MON OWN discrete from the FMGC 1 (1CA1) (from pin AE/12G to pin AE/3E)
ASM 228503.
- repair the above wiring.
- replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
- do a check and repair the
wiring of the CMD 1 SW MON discrete from the FCU (2CA) to the FMGC 1 (1CA1) ASM 228503.
C. Do the test given in Para. 3.