The AP 1 Pushbutton Switch does not come on when the AP 1 is engaged
TASK 22-11-00-810-817-A
The AP 1 Pushbutton Switch does not come on when the AP 1 is engaged
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-860-050-A Subtask 22-11-00-865-060-A
Subtask 22-11-00-810-066-A
Subtask 22-11-00-860-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:07 UTC
The AP 1 Pushbutton Switch does not come on when the AP 1 is engaged
1. Possible Causes
- FCU [2CA]
wiring of AP 1 ENGD MON OWN and AP 1 ENGD COM OWN discretes from the FCU (2CA) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-10-00-710-005 | Operational Test of the Indicator Lights and Displays of the FCU |
| AMM 22-81-12-000-001 | Removal of the FCU |
| AMM 22-81-12-400-001 | Installation of the FCU |
| ASM 228503 | |
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 24-41-00-862-002 | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
Subtask 22-11-00-860-050-A Subtask 22-11-00-865-060-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-11-00-710-070-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AUTO FLT/FCU/1 | 9CA1 | B05 |
| 49VU | AUTO FLT/FMGC/1 | 10CA1 | B02 |
C. Test
4. Fault Isolation| ACTION | RESULT |
|---|---|
1.On the FCU:
| This pushbutton switch comes on. |
Subtask 22-11-00-810-066-A
A. If the AP 1 pushbutton switch does not come on:
Subtask 22-11-00-710-071-A - do the operational test of the indicator lights and displays of the FCU AMM 22-10-00-710-005
- make sure that the AP 1 pushbutton switch comes on.
- replace the FCU [2CA] AMM 22-81-12-000-001 and AMM 22-81-12-400-001.
- do a check and repair the
wiring of AP 1 ENGD MON OWN and AP 1 ENGD COM OWN discretes from the FCU (2CA) to the first terminal block ASM 228503.
B. Do the test given in Para. 3.
5. Close-upSubtask 22-11-00-860-051-A