Loss of the FMGC 2 Bus Feedback


TASK 22-11-00-810-804-A
Loss of the FMGC 2 Bus Feedback


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FMGC OWN A (MON) bus from the FMGC 2 (1CA2) to the first terminal block
  • wiring of the FMGC MON OUT (MON) bus on the FMGC 2 (1CA2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-11-00-710-088-A
A. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
4. Fault Isolation
Subtask 22-11-00-810-053-A
A. If the test gives the maintenance message AFS: FMGC2/C-M ARINC LINK:
   (1) If the fault continues:
  • do a check of the wiring of the FMGC OWN A (MON) bus from the FMGC 2 (1CA2) to the first terminal block ASM 228602.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the FMGC MON OUT (MON) bus on the FMGC 2 (1CA2), pin AE/14A, 14B to pin AB/9J, 9K ASM 228602.
Subtask 22-11-00-710-089-A
B. Do the test given in Para. 3.