Failure of the FMGC 2
TASK 22-11-00-810-802-A
Failure of the FMGC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-11-00-865-069-A
Subtask 22-11-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:06 UTC
Failure of the FMGC 2
1. Possible Causes
- FMGC-2 [1CA2]
- wiring of the 28VDC and 28VDC GND signals
short to ground between the circuit breaker (10CA2) and the A/THR 2 relays (5CA2), (17CA2) and (18CA2) - C/B-AUTO FLT/FMGC/2 [10CA2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 223101 | |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228401 | |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
Subtask 22-11-00-865-069-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-11-00-710-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/FMGC/2 | 10CA2 | M17 |
B. Test
(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
(a) If the circuit breaker (10CA2) is open, refer to Para. 4.B.
4. Fault Isolation(1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FMGC 2.
(a) If the circuit breaker (10CA2) is open, refer to Para. 4.B.
Subtask 22-11-00-810-051-A
A. If the circuit breaker (10CA2) is closed and if the test gives the maintenance message AFS : FMGC2:
Subtask 22-11-00-810-077-A - remove the FMGC-2 [1CA2] AMM 22-83-34-000-001
- do a check and repair the wiring of the 28VDC and 28VDC GND signals at the FMGC2 connector ASM 228401
- replace the FMGC-2 [1CA2] and AMM 22-83-34-400-001.
B. If the circuit breaker (10CA2) is open:
Subtask 22-11-00-710-053-A - close this circuit breaker.
- replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check for a short to ground between the circuit breaker (10CA2) and the FMGC 2 (1CA2) ASM 228401
- do a check for a
short to ground between the circuit breaker (10CA2) and the A/THR 2 relays (5CA2), (17CA2) and (18CA2) ASM 223101.
- repair the above wirings.
- replace the C/B-AUTO FLT/FMGC/2 [10CA2] .
C. Do the test given in Para. 3.