W DOC AIRBUS | TSM A320F

ACSC2 Wiring Fault


TASK 21-61-00-810-925-A
ACSC2 Wiring Fault


1. Possible Causes
  • CONT-AIR COND SYSTEM 2 [57HH]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
ASM 216301
3. Fault Confirmation
Subtask 21-61-00-710-222-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault Isolation
Subtask 21-61-00-810-276-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ACSC2 X-BLEED VLV:
   (1) If the fault continues:
  • do a check and repair the wiring ASM 216301 from:
  • the X-BLEED VLV (6HV) to the ACSC2 (57HH).
Subtask 21-61-00-710-223-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:00 UTC