CIDS 2 receives no Data from ACSC2


TASK 21-61-00-810-920-A
CIDS 2 receives no Data from ACSC2


1. Possible Causes
  • wiring
  • DIR-CIDS, 2 [102RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
ASM 216303
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 21-61-00-710-214-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 21-61-00-810-259-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 21-61-00-810-260-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message ACSC2(57HH)/SDAC2(1WV2)/ DIR2(102RH):
  • do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
   (1) If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
   (2) If the fault continues:
     (a) Do a check and repair if necessary the connector pin at the connector 57HH/BE for the CIDS option.
  • Pin BE3 to ground.
   (3) If the fault continues:
  • do a check of the wiring from:
  • ASM 216303 the ACSC2 (57HH/AA) pin 1D to the DIR-CIDS, 2 (102RH/AA) pin 6A,
  • the ACSC2 (57HH/AA) pin 1E to the DIR-CIDS, 2 (102RH/AA) pin 6B.
   (4) If the fault continues:
Replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 21-61-00-710-215-A ** ON A/C NOT FOR ALL
C. Do the test as given in the Para. 3.A.