High Difference in Pack Discharge Temperatures (Condensor fault)


TASK 21-61-00-810-905-A
High Difference in Pack Discharge Temperatures (Condensor fault)


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 12-33-21-618-001
Pre-conditioning through the LP Ground Connection
AMM 21-52-32-000-001
Removal of the Condenser
AMM 21-52-32-400-001
Installation of the Condenser
3. Fault Confirmation
Subtask 21-61-00-710-187-A
A. Test
   (1) Do the pre-conditioning with the APU AMM 12-33-21-618-001.
   (2) Make sure that the pack 1 inlet-pressure indication on the ECAM BLEED page is > 20 PSI.
   (3) Compare the PACK 1 & 2 outlet temperatures on the ECAM BLEED page during the next work step.
NOTE: PACK 1 & 2 outlet temperatures must be almost equal.
   (4) On the AIR COND panel 30VU:
  • put the COCKPIT, the FWD CABIN and the AFT CABIN selectors to the HOT position,
  • wait for 10 minutes,
  • put the COCKPIT, the FWD CABIN and the AFT CABIN selectors to the COLD position.
4. Fault Isolation
Subtask 21-61-00-860-094-A
A. Safety Precautions
   (1) Before you do any corrective actions you must stop the pre-conditioning with the APU AMM 12-33-21-618-001.
Subtask 21-61-00-810-237-A
B. If the test shows unequal PACK 1 & 2 outlet temperatures:
  • make a full visual inspection of the Pack 1 & 2 condensors for cracks.
Subtask 21-61-00-810-238-A
C. If the inspection shows cracks:
5. Close-up
Subtask 21-61-00-860-095-A
A. Do the test given in Para. 3.