ECAM Indication only - AIR COND CTL 2-A FAULT
TASK 21-61-00-810-900-A
ECAM Indication only - AIR COND CTL 2-A FAULT
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-196-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-243-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:58 UTC
ECAM Indication only - AIR COND CTL 2-A FAULT
1. Possible Causes
- wiring
- CONT-AIR COND SYSTEM 2 [57HH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 216101 | |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
Subtask 21-61-00-710-196-A ** ON A/C NOT FOR ALL
A. Do a read out of the POST FLIGHT REPORT.
4. Fault IsolationSubtask 21-61-00-810-243-A ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT shows the warning AIR COND CTL 2-A FAULT without any associated maintenance messages:
Subtask 21-61-00-710-197-A ** ON A/C NOT FOR ALL - Do a check of the wiring ASM 216101 from,
- the ACSC2 (57HH/C) pin 3 to the CB (55HH) (28VDC supply) and,
- the ACSC2 (57HH/C) pin 4 to the CB (53HH) (115VAC supply).
If the fault continues: - replace the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
B. Do the procedure as in Para. 3. A.