Pack 2 Discharge Pressure Sensor Fault
TASK 21-61-00-810-897-A
Pack 2 Discharge Pressure Sensor Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-184-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-61-00-810-232-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:58 UTC
Pack 2 Discharge Pressure Sensor Fault
1. Possible Causes
- P2 PACK DISCH PRESS SENSOR [20HH]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216102 | |
| AMM 21-61-14-000-001 | Removal of the Pack Discharge Pressure Sensor |
| AMM 21-61-14-400-001 | Installation of the Pack Discharge Pressure Sensor |
Subtask 21-61-00-710-184-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 21-61-00-810-232-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 DISCHARGE PRESS SENSOR(20HH):
Subtask 21-61-00-720-068-A ** ON A/C NOT FOR ALL - replace the P2 PACK DISCH PRESS SENSOR [20HH] AMM 21-61-14-000-001 and AMM 21-61-14-400-001.
- do a check of the wiring ASM 216102 from:
- the SENSOR (20HH) to the ACSC 2 (57HH) and,
- the SENSOR (20HH) to ground.
B. Do the test as given in the Para. 3.A.