W DOC AIRBUS | TSM A320F

ACSC1/ACSC2 Bus 2 Fault


TASK 21-61-00-810-892-A
ACSC1/ACSC2 Bus 2 Fault


1. Possible Causes
  • wiring
  • CONT-AIR COND SYSTEM 1 [47HH]
  • CONT-AIR COND SYSTEM 2 [57HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
ASM 216103
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
3. Fault Confirmation
Subtask 21-61-00-710-178-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault Isolation
Subtask 21-61-00-810-226-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ACSC1(47HH)/ACSC2(57HH) /WRG: ACSC1 BUS2 TO ACSC2:
  • do a check and repair the wiring ASM 216103 from:
  • the ACSC1 (47HH) connector AA/6E to the ACSC2 (57HH) connector AA/4E,
  • the ACSC1 (47HH) connector AA/6F to the ACSC2 (57HH) connector AA/4F.
   (1) If the fault continues:
   (2) If the fault continues:
Subtask 21-61-00-720-063-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:58 UTC