W DOC AIRBUS | TSM A320F

ACSC CIDS 1+2 Input Fault


TASK 21-61-00-810-887-A
ACSC CIDS 1+2 Input Fault


1. Possible Causes
  • wiring
  • CONT-AIR COND SYSTEM 1 [47HH]
  • CONT-AIR COND SYSTEM 2 [57HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
ASM 216301
ASM 216303
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
3. Fault Confirmation
Subtask 21-61-00-710-173-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do a read out of the POST FLIGHT REPORT and check for CLASS 2 Chapter 21 messages.
   (2) Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 21-61-00-810-221-B ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance messages CIDS1(101RH) +CIDS2(102RH):
  • do a check of the wiring from:
  • ASM 216303 the ACSC1 (47HH/AA) pin 1D to the DIR-SIDS, 1 (101RH/AA) pin 6A,
  • the ACSC1 (47HH/AA) pin 1E to the DIR-SIDS, 1 (101RH/AA) pin 6B,
  • ASM 216301 the ACSC2 (57HH/AA) pin 1D to the DIR-SIDS, 2 (102RH/AA) pin 6A and,
  • the ACSC2 (57HH/AA) pin 1E to the DIR-SIDS, 2 (102RH/AA) pin 6B.
   (1) If the fault continues:
Replace the CONT-AIR COND SYSTEM 1 [47HH] and the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
[Rev.8 from Aug 2018] 2026.04.04 04:24:57 UTC