ACSC CIDS 1+2 Input Fault
TASK 21-61-00-810-887-A
ACSC CIDS 1+2 Input Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-173-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-221-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:57 UTC
ACSC CIDS 1+2 Input Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| ASM 216301 | |
| ASM 216303 | |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
Subtask 21-61-00-710-173-A ** ON A/C NOT FOR ALL
A. Test
(1) Do a read out of the POST FLIGHT REPORT and check for CLASS 2 Chapter 21 messages.
(2) Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation(1) Do a read out of the POST FLIGHT REPORT and check for CLASS 2 Chapter 21 messages.
(2) Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
Subtask 21-61-00-810-221-B ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance messages CIDS1(101RH) +CIDS2(102RH):
Replace the CONT-AIR COND SYSTEM 1 [47HH] and the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
- do a check of the wiring from:
- ASM 216303 the ACSC1 (47HH/AA) pin 1D to the DIR-SIDS, 1 (101RH/AA) pin 6A,
- the ACSC1 (47HH/AA) pin 1E to the DIR-SIDS, 1 (101RH/AA) pin 6B,
- ASM 216301 the ACSC2 (57HH/AA) pin 1D to the DIR-SIDS, 2 (102RH/AA) pin 6A and,
- the ACSC2 (57HH/AA) pin 1E to the DIR-SIDS, 2 (102RH/AA) pin 6B.
Replace the CONT-AIR COND SYSTEM 1 [47HH] and the CONT-AIR COND SYSTEM 2 [57HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.