W DOC AIRBUS | TSM A320F

ACSC2 Lane 2 115VAC Supply Fault


TASK 21-61-00-810-885-A
ACSC2 Lane 2 115VAC Supply Fault


1. Possible Causes

2. Fault Confirmation
Subtask 21-61-00-710-171-A ** ON A/C NOT FOR ALL
A. Not applicable.
3. Fault Isolation
Subtask 21-61-00-810-219-A ** ON A/C NOT FOR ALL
A. If the GROUND REPORT gives the maintenance message TEMP CTL SYS 2 CHAN B 115VAC SUPPLY INTERRUPT:
  • do a check for 115VAC at the ACSC2 (57HH)C pin 1.
   (1) If the fault continues:
  • do the trouble shooting of the electrical power supply (Ref. TSM Chapter 24).
[Rev.8 from Aug 2018] 2026.04.04 04:24:57 UTC