W DOC AIRBUS | TSM A320F

Several Pack 2 'XX' indications on ECAM


TASK 21-61-00-810-872-A
Several Pack 2 'XX' indications on ECAM


1. Possible Causes
  • C/B-AIR COND/PACK TEMP/CTL SYS1/2/115VAC [21HH]
  • C/B-AIR COND/PACK TEMP CTL SYS2/2/115VAC [22HH]
  • P2 CONTROLLER [27HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
3. Fault Confirmation
Subtask 21-61-00-710-156-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
4. Fault Isolation
Subtask 21-61-00-810-204-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 CONT and the Pack 2 indications which follow,
  • pack flow,
  • pack outlet temperature,
  • temperature control valve position,
  • pack compressor outlet temperature,
    show amber XX on the ECAM BLEED page:
   (1) Open and then close the C/B-AIR COND/PACK TEMP/CTL SYS1/2/115VAC [21HH] and the C/B-AIR COND/PACK TEMP CTL SYS2/2/115VAC [22HH] .
NOTE: This will do a reset of the Pack 2 controller.
     (a) If, after the reset has been done, some of the indications still show amber XX on the ECAM BLEED page:
  • do the related trouble shooting procedure of the applicable XX indication/s refer to the Fault Symptom List.
   (2) If the fault continues:
5. Close-up
Subtask 21-61-00-720-056-A ** ON A/C NOT FOR ALL
A. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:57 UTC