ACSC2 / Pack 2 Bypass Valve Fault


TASK 21-61-00-810-869-A
ACSC2 / Pack 2 Bypass Valve Fault


1. Possible Causes
  • CONT-AIR COND SYSTEM 2 [57HH]
  • VALVE-TURBINE BYPASS [30HH]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
ASM 216102
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 21-61-53-000-001
Removal of the Turbine Bypass Valve
AMM 21-61-53-400-001
Installation of the Turbine Bypass Valve
3. Fault Confirmation
Subtask 21-61-00-710-158-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault Isolation
Subtask 21-61-00-810-206-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ACSC2(57HH)/P2 BYPASS VALVE(30HH):
   (1) If the fault moves with the ACSC2:
  • swap back the ACSC1 (57HH) and replace the CONT-AIR COND SYSTEM 2 [57HH] (ACSC2 57HH).
   (2) If the fault does not move with the ACSC2:
   (3) If the fault continues:
  • do a check and repair the wiring ASM 216102 from:
  • the VALVE (30HH) to the ACSC2 (57HH) and,
  • the VALVE (30HH) to ground.
Subtask 21-61-00-720-058-A ** ON A/C NOT FOR ALL
B. Do the test as given in the PARA. 3.A.