Pack 1 Control - No Test Result
TASK 21-61-00-810-863-A
Pack 1 Control - No Test Result
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-144-A 4. Fault Isolation
Subtask 21-61-00-810-173-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:56 UTC
Pack 1 Control - No Test Result
1. Possible Causes
- P1 FLOW CTL VALVE [11HB]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 215101 | |
| AMM 21-51-51-000-001 | Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-51-51-400-001 | Installation of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
Subtask 21-61-00-710-144-A 4. Fault Isolation
Subtask 21-61-00-810-173-A
A. If the test gives the message NO TEST RESULT RECEPTION FROM P1 CONT:
Subtask 21-61-00-810-174-A - replace the P1 FLOW CTL VALVE [11HB] AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
- do a check and the repair the wiring ASM 215101:
from the PC1 (7HH)AB/6B to the FCV (11HB)A/D,
from the PC1 (7HH)AA/7B to the FCV (8HB)A/C,
from the FCV (11HB)A/B to the ground.
B. Do the test as given in the Para. 3.A.