Pack 1 Air Inlet Actuator Fault
TASK 21-61-00-810-849-A
Pack 1 Air Inlet Actuator Fault
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-136-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-165-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:55 UTC
Pack 1 Air Inlet Actuator Fault
CAUTION:
DO NOT SWAP THE PACK/ACS CONTROLLERS. THIS CAN CAUSE DAMAGE TO THEM IF THERE IS AN ELECTRICAL FAULT IN THE ACTUATOR.
1. Possible Causes2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216104 | |
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 21-61-51-000-001 | Removal of the Air-Inlet Flap Actuator |
| AMM 21-61-51-400-001 | Installation of the Air-Inlet Flap Actuator 8HH and 28HH |
Subtask 21-61-00-710-136-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the pre-conditioning through the HP ground connection AMM 12-33-21-618-001 or with the APU AMM 12-33-21-618-001.
(2) Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-61-00-710-136-B ** ON A/C NOT FOR ALL (1) Do the pre-conditioning through the HP ground connection AMM 12-33-21-618-001 or with the APU AMM 12-33-21-618-001.
(2) Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
A. Test
(1) Do the pre-conditioning through the HP ground connection AMM 12-33-21-618-001 or with the APU AMM 12-33-21-618-001.
(2) Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault Isolation(1) Do the pre-conditioning through the HP ground connection AMM 12-33-21-618-001 or with the APU AMM 12-33-21-618-001.
(2) Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-61-00-810-165-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P1 RAM AIR IN ACTUATOR:
Subtask 21-61-00-810-165-B ** ON A/C NOT FOR ALL - replace the P1 RAM AIR IN ACTUATOR [8HH] (referred to as ACTUATOR (8HH)) AMM 21-61-51-000-001 and AMM 21-61-51-400-001.
- do a check and repair the wiring ASM 216104 from:
- the ACTUATOR (8HH) to the PC 1 (7HH) and,
- the ACTUATOR (8HH) to ground.
- replace the P1 CONTROLLER [7HH] AMM 21-61-34-000-001 and AMM 21-61-34-400-001.
A. If the test gives the maintenance message P1 RAM AIR IN ACTUATOR(8HH):
Subtask 21-61-00-720-051-A - replace the P1 RAM AIR IN ACTUATOR [8HH] AMM 21-61-51-000-001 and AMM 21-61-51-400-001.
- do a check and repair the wiring ASM 216104 from:
- the ACTUATOR (8HH) to the ACSC1 (47HH) and,
- the ACTUATOR (8HH) to ground.
- replace the CONT-AIR COND SYSTEM 1 [47HH] AMM 21-61-34-000-002 and AMM 21-61-34-400-002.
B. Do the test as given in the Para. 3.A.