Pack 1 Compressor Temperature Sensor / Compressor Overheat Sensor Disagree
TASK 21-61-00-810-843-A
Pack 1 Compressor Temperature Sensor / Compressor Overheat Sensor Disagree
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-129-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-158-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:55 UTC
Pack 1 Compressor Temperature Sensor / Compressor Overheat Sensor Disagree
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216104 | |
| AMM 21-61-11-000-001 | Removal of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-11-400-001 | Installation of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-12-000-001 | Removal of the Compressor Overheat - Temperature Sensor |
| AMM 21-61-12-400-001 | Installation of the Compressor Overheat - Temperature Sensor |
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
Subtask 21-61-00-710-129-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault IsolationNOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
Subtask 21-61-00-810-158-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P1 COMP TEMP/OVHT SENSOR DISAGREE:
Subtask 21-61-00-710-130-A ** ON A/C NOT FOR ALL - replace the SENSOR-COMPRESSOR OVHT [15HH] AMM 21-61-12-000-001 and AMM 21-61-12-400-001.
- replace the SENSOR-COMPRESSOR TEMPERATURE [12HH] AMM 21-61-11-000-001 and AMM 21-61-11-400-001.
- do a check and repair the wiring ASM 216104 between:
SENSOR (15HH) connector A/C and PC 1 (7HH) connector AB/1C,
SENSOR (15HH) connector A/B and PC 1 (7HH) connector AB/1B,
SENSOR (15HH) connector A/A and PC 1 (7HH) connector AB/1A.
- do a check and repair the wiring ASM 216104 between:
SENSOR (12HH) connector A/C and PC 1 (7HH) connector AA/14C,
SENSOR (12HH) connector A/B and PC 1 (7HH) connector AA/14D,
SENSOR (12HH) connector A/A and PC 1 (7HH) connector AA/15A,
- replace the P1 CONTROLLER [7HH] AMM 21-61-34-000-001 and AMM 21-61-34-400-001.
B. Do the test as given in the Para. 3.A.