W DOC AIRBUS | TSM A320F

Pack 1 Controller Pin Program Mismatch


TASK 21-61-00-810-838-A
Pack 1 Controller Pin Program Mismatch


1. Possible Causes
  • P1 CONTROLLER [7HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
AMM 21-63-00-710-004
Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU
3. Fault Confirmation
Subtask 21-61-00-710-120-A ** ON A/C NOT FOR ALL
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU AMM 21-63-00-710-004.
4. Fault Isolation
Subtask 21-61-00-810-151-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P1 PIN PROGRAM MISMATCH:
Subtask 21-61-00-710-121-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:24:55 UTC