Pack 2 Outlet Temperature Sensor Fault
TASK 21-61-00-810-831-A
Pack 2 Outlet Temperature Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-110-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-123-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-860-080-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:54 UTC
Pack 2 Outlet Temperature Sensor Fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216102 | |
| AMM 21-61-15-000-001 | Removal of the Pack Outlet - Temperature Sensors |
| AMM 21-61-15-400-001 | Installation of the Pack Outlet - Temperature Sensors |
| AMM 21-63-42-210-001 | Detailed Visual Inspection of Trim-Air Check-Valves Flappers for Condition and Operation |
Subtask 21-61-00-710-110-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-61-00-710-110-B ** ON A/C NOT FOR ALL 4. Fault IsolationNOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
Subtask 21-61-00-810-123-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 OUTLET TEMP SENSOR:
Subtask 21-61-00-810-123-B ** ON A/C NOT FOR ALL - replace the SENSOR-PACK OUTLET TEMP [34HH] (referred to as SENSOR (34HH)) AMM 21-61-15-000-001 and AMM 21-61-15-400-001.
- do a check and repair the wiring between:
SENSOR (34HH) connector A/C and PC 2 (27HH) connector AB/12A,
SENSOR (34HH) connector A/B and PC 2 (27HH) connector AB/12B,
SENSOR (34HH) connector A/A and PC 2 (27HH) connector AB/11D ASM 216102.
- do a visiual inspection of the trim-air check-valve flappers AMM 21-63-42-210-001, and replace this valve if nessesary.
A. If the test gives the maintenance message P2 OUT TEMP SENSOR(34HH):
Subtask 21-61-00-710-111-A - replace the SENSOR-PACK OUTLET TEMP [34HH] AMM 21-61-15-000-001 and AMM 21-61-15-400-001.
- do a check and repair the wiring ASM 216102 from:
- the SENSOR (34HH) to the ACSC2 (57HH) and,
- the SENSOR (34HH) to ground.
- do a visual inspection of the P2 CHECK VALVE TRIM AIR [19HM] flappers AMM 21-63-42-210-001, and replace this valve if nessesary.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-61-00-860-080-A
A. Put the aircraft back to its initial configuration.