W DOC AIRBUS | TSM A320F

Pack 2 Pressure Inlet Sensor Fault


TASK 21-61-00-810-823-A
Pack 2 Pressure Inlet Sensor Fault


1. Possible Causes
  • P2 PRESS INL SENSOR [36HH]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
AWM 216109
AMM 21-61-16-000-001
Removal of the Pack-Inlet Pressure Sensor
AMM 21-61-16-400-002
Installation of the Pack-Inlet Pressure Sensor
3. Fault Confirmation
Subtask 21-61-00-710-094-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
4. Fault Isolation
Subtask 21-61-00-810-115-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 PRESS INL SENSOR:
   (1) If the fault continues:
  • do a check and repair the wiring between:
    CONNECTOR (7560VC) pin C and PC 2 (27HH) connector AA/10C,
    CONNECTOR (7560VC) pin B and PC 2 (27HH) connector AA/10D,
    CONNECTOR (7560VC) pin A and PC 2 (27HH) connector AB/15C,
    CONNECTOR (7560VC) pin D and PC 2 (27HH) connector AB/15D AWM 216109 and AWM 216109.
Subtask 21-61-00-710-095-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-61-00-860-072-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:54 UTC