Pack 2 Pressure Inlet Sensor Fault
TASK 21-61-00-810-823-A
Pack 2 Pressure Inlet Sensor Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-094-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-115-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-860-072-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:54 UTC
Pack 2 Pressure Inlet Sensor Fault
1. Possible Causes
- P2 PRESS INL SENSOR [36HH]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| AWM 216109 | |
| AMM 21-61-16-000-001 | Removal of the Pack-Inlet Pressure Sensor |
| AMM 21-61-16-400-002 | Installation of the Pack-Inlet Pressure Sensor |
Subtask 21-61-00-710-094-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault IsolationNOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
Subtask 21-61-00-810-115-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 PRESS INL SENSOR:
Subtask 21-61-00-710-095-A ** ON A/C NOT FOR ALL - replace the P2 PRESS INL SENSOR [36HH] AMM 21-61-16-000-001 and AMM 21-61-16-400-002.
- do a check and repair the wiring between:
CONNECTOR (7560VC) pin C and PC 2 (27HH) connector AA/10C,
CONNECTOR (7560VC) pin B and PC 2 (27HH) connector AA/10D,
CONNECTOR (7560VC) pin A and PC 2 (27HH) connector AB/15C,
CONNECTOR (7560VC) pin D and PC 2 (27HH) connector AB/15D AWM 216109 and AWM 216109.
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-61-00-860-072-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.