Pack 2 Electrical Component with Short Circuit (AIR PACK 2 REGUL FAULT)
TASK 21-61-00-810-821-A
Pack 2 Electrical Component with Short Circuit (AIR PACK 2 REGUL FAULT)
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-865-052-A
Subtask 21-61-00-810-273-B ** ON A/C NOT FOR ALL
Subtask 21-61-00-860-070-A
[Rev.8 from Aug 2018]
2026.04.04 04:38:53 UTC
Pack 2 Electrical Component with Short Circuit (AIR PACK 2 REGUL FAULT)
1. Possible Causes
- FLOW CTL UNIT - PACK 2 [24HB]
- P2 FLOW SENSOR [9HB]
- SENSOR-DELTA P, PACK 2 [24HB2]
- P2 RAM AIR IN ACTUATOR [28HH]
- P2 CONTROLLER [27HH]
- CONT-AIR COND SYSTEM 2 [57HH]
- SENSOR-WATER EXTRACTOR TEMPERATURE [31HH]
- VALVE-TURBINE BYPASS [30HH]
- SENSOR-COMPRESSOR TEMPERATURE [32HH]
- P2 FLOW CTL VALVE [8HB]
- P2 PRESS INL SENSOR [36HH]
- wiring
- SENSOR-PRESS, PACK 2 INLET [24HB1]
- SDAC
- TEMP SENSOR RH MIXER [25HK]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WATER - SOAPY SOLUTION |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| ASM 215101 | |
| AMM 21-51-11-000-001 | Removal of the Differential Pressure Sensor |
| AMM 21-51-11-400-001 | Installation of the Differential Pressure Sensor |
| AMM 21-51-13-000-001 | Removal of the Pack-Inlet Pressure Sensor |
| AMM 21-51-13-400-001 | Installation of the Pack-Inlet Pressure Sensor |
| AMM 21-51-51-000-001 | Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-51-51-400-001 | Installation of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| ASM 216101 | |
| ASM 216102 | |
| ASM 216104 | |
| AWM 216106 | |
| AWM 216107 | |
| AWM 216108 | |
| AWM 216109 | |
| AMM 21-61-11-000-001 | Removal of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-11-400-001 | Installation of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-13-000-001 | Removal of the Water-Extractor Temperature Sensors |
| AMM 21-61-13-400-001 | Installation of the Water-Extractor Temperature Sensors |
| AMM 21-61-16-000-001 | Removal of the Pack-Inlet Pressure Sensor |
| AMM 21-61-16-400-002 | Installation of the Pack-Inlet Pressure Sensor |
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 21-61-51-000-001 | Removal of the Air-Inlet Flap Actuator |
| AMM 21-61-51-400-001 | Installation of the Air-Inlet Flap Actuator 8HH and 28HH |
| AMM 21-61-53-000-001 | Removal of the Turbine Bypass Valve |
| AMM 21-61-53-400-001 | Installation of the Turbine Bypass Valve |
| AMM 21-63-16-000-001 | Removal of the Mixer Temperature Sensor |
| AMM 21-63-16-400-001 | Installation of the Mixer Temperature Sensor |
Subtask 21-61-00-865-052-A
A. Open this(these) circuit breaker(s):
Subtask 21-61-00-865-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
B. Close this(these) circuit breaker(s):
Subtask 21-61-00-710-090-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/2/115VAC | 21HH | W22 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/2/115VAC | 22HH | Y20 |
C. Test
(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
Subtask 21-61-00-710-090-B ** ON A/C NOT FOR ALL (1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
NOTE: If the test finds a fault the PC gives a fault code for shop maintenance and also the related CFDS message(s) (refer to chapter 21-63-00 page block 301).
C. Test
(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
(2) Perform a leak check at the FCV Sensor plate.
(c) Apply a WATER - SOAPY SOLUTION to the connections behind the sensor plate to search for a leak.
4. Fault Isolation(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
(2) Perform a leak check at the FCV Sensor plate.
NOTE: This procedure is only applicable for FCV P/N 1806A0000-02, 1806A0000-02 Amdt A, 1806B0000-01, 1806B0000-01 Amdt A, 1806B0000-01 Amdt AB, 1806B0000-01 Amdt B and 1806B0000-02.
(a) On the AIR COND panel 30VU: - make sure that the PACK pushbutton switch is in the OFF position.
(c) Apply a WATER - SOAPY SOLUTION to the connections behind the sensor plate to search for a leak.
Subtask 21-61-00-810-273-B ** ON A/C NOT FOR ALL
A. If a leakage is found:
Subtask 21-61-00-810-113-A ** ON A/C NOT FOR ALL - replace the FLOW CTL UNIT - PACK 2 [24HB] , AMM 21-51-51-000-001 and AMM 21-51-51-400-001
B. * If the post flight report gives the warning AIR PACK 2 REGUL FAULT without a maintenance message and,
* no AIR PACK 2 REGUL FAULT shows on the ECAM upper DU and,
* no maintenance message shows:
Subtask 21-61-00-810-187-B ** ON A/C NOT FOR ALL * no AIR PACK 2 REGUL FAULT shows on the ECAM upper DU and,
* no maintenance message shows:
- replace the P2 FLOW SENSOR [9HB] AMM 21-51-11-000-001 and AMM 21-51-11-400-001.
** If the post flight report gives the warning AIR PACK 2 REGUL FAULT and,
** the ECAM upper DU gives the warning AIR PACK 2 REGUL FAULT or,
*** If the post flight report gives the warning AIR PACK 2 REGUL FAULT with,
*** the maintenance message NO DATA FROM P2 CONT and,
*** the operational test of the pack-temperature control system gives the maintenance message NO TEST RECEPTION FROM P2 CONT: - do the work steps which follow.
NOTE: Additional Information
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216102,
ASM 216104 and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216102,
ASM 216104 and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
C. Check for Short Circuit at the P2 RAM AIR IN ACTUATOR [28HH] 115VAC Supply Lines
(1) Remove the P2 CONTROLLER [27HH]
AMM 21-61-34-000-001:
(2) Disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] :
Subtask 21-61-00-810-188-A ** ON A/C NOT FOR ALL (1) Remove the P2 CONTROLLER [27HH]
AMM 21-61-34-000-001:
(2) Disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] :
- at the electrical connector (28HH/A) do a check for a short circuit between,
* pins J and N and,
* GND and pins J and N, - if there is a short circuit repair the related wiring between,
* connector (28HH/A) pin J and PC connector (27HH/AB) pin 15A,
* connector (28HH/A) pin N and PC connector (27HH/AB) pin 14B. - if there is no short circuit in the wiring replace the P2 RAM AIR IN ACTUATOR [28HH]
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - install the P2 CONTROLLER [27HH]
AMM 21-61-34-400-001. - connect the electrical connector (28HH/A) to the P2 RAM AIR IN ACTUATOR [28HH] .
D. If the fault continues:
(1) Swap the PC 2 (27HH) and the PC 1 (7HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
(2) If the fault moves with the PC 2:
Subtask 21-61-00-810-189-B ** ON A/C NOT FOR ALL (1) Swap the PC 2 (27HH) and the PC 1 (7HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
(2) If the fault moves with the PC 2:
- swap back the PC 2 (27HH) and the PC 1 (7HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001. - replace the P2 CONTROLLER [27HH]
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
- swap back the PC 2 (27HH) and the PC 1 (7HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
E. If the fault continues:
(1) Disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
Subtask 21-61-00-810-190-A ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (31HH/A) do a check for voltage between,
* pins E and F.
- replace the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH]
AMM 21-61-13-000-001 and,
AMM 21-61-13-400-001.
- disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] ,
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (31HH/A) do a check for voltage again.
- replace the P2 RAM AIR IN ACTUATOR [28HH]
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - connect the electrical connector (31HH/A).
- connect the electrical connector (28HHA) AMM 21-61-51-400-001.
- repeat para. 4.E.(1).(b) for:
* connector (30HH/A) and the VALVE-TURBINE BYPASS [30HH]
AMM 21-61-53-000-001 and,
AMM 21-61-53-400-001,
* connector (32HH/A) and the SENSOR-COMPRESSOR TEMPERATURE [32HH]
AMM 21-61-11-000-001 and,
AMM 21-61-11-400-001,
* connector (8HB/A) and the P2 FLOW CTL VALVE [8HB]
AMM 21-51-51-000-001 and,
AMM 21-51-51-400-001. - connect the electrical connector (31HH/A).
F. If the fault continues:
(1) Disconnect the electrical connector (7560VC/A)
AMM 21-61-16-000-001.
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin E and PC 2 connector (27HH/AA) pin 14A,
* connector (31HH/A) pin F and PC 2 connector (27HH/AA) pin 14B.
(b) If there is a short circuit repair the related wiring between,
* connector (28HH/A) pin A and PC 2 connector (27HH/AA) pin 11D,
* connector (28HH/A) pin B and PC 2 connector (27HH/AA) pin 12A,
* connector (28HH/A) pin C and PC 2 connector (27HH/AA) pin 12B.
Subtask 21-61-00-810-113-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (7560VC/A)
AMM 21-61-16-000-001.
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (7560VC) do a check for 15VDC from the pack controller primary channel between,
* pins A and C (+15VDC) and,
* pins D and C (-15VDC).
- replace the P2 PRESS INL SENSOR [36HH]
AMM 21-61-16-000-001 and,
AMM 21-61-16-400-002.
- remove the P2 CONTROLLER [27HH]
AMM 21-61-34-000-001, - disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
- at the electrical connector (31HH/A) do a check for a short circuit between,
* pins E and F and,
* GND and pins E and F.
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin E and PC 2 connector (27HH/AA) pin 14A,
* connector (31HH/A) pin F and PC 2 connector (27HH/AA) pin 14B.
- connect the electrical connector (31HH/A).
- disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] ,
- at the electrical connector (28HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (28HH/A) pin A and PC 2 connector (27HH/AA) pin 11D,
* connector (28HH/A) pin B and PC 2 connector (27HH/AA) pin 12A,
* connector (28HH/A) pin C and PC 2 connector (27HH/AA) pin 12B.
- connect the electrical connector (28HH/A).
G. * If the post flight report gives the warning AIR PACK 2 REGUL FAULT without a maintenance message and,
* no AIR PACK 2 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
Subtask 21-61-00-810-187-C ** ON A/C NOT FOR ALL * no AIR PACK 2 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
- replace the SENSOR-DELTA P, PACK 2 [24HB2] ,
AMM 21-51-11-000-001 and AMM 21-51-11-400-001 (less probable cause for this failure).
- replace the FLOW CTL UNIT - PACK 2 [24HB] ,
AMM 21-51-51-000-001 and AMM 21-51-51-400-001. - no further action is necessary.
** If the post flight report gives the warning AIR PACK 2 REGUL FAULT and,
** the ECAM upper DU shows the warning AIR PACK 2 REGUL FAULT or: - do the work steps which follow.
NOTE: Additional Information
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216101,
ASM 216102,
AWM 216106,
AWM 216107,
AWM 216108and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216101,
ASM 216102,
AWM 216106,
AWM 216107,
AWM 216108and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
H. Check for short circuit at the P2 RAM AIR IN ACTUATOR [28HH] 115VAC supply lines
(1) Remove the CONT-AIR COND SYSTEM 2 [57HH] ,
AMM 21-61-34-000-002:
(2) Disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] :
Subtask 21-61-00-810-188-B ** ON A/C NOT FOR ALL (1) Remove the CONT-AIR COND SYSTEM 2 [57HH] ,
AMM 21-61-34-000-002:
(2) Disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] :
- do a check for a short circuit between,
* pins J and K and,
* GND and pins J and K. - if there is a short circuit repair the related wiring between,
* connector (28HH/A) pin J and ACSC2 connector (57HH/AB) pin 15J,
* connector (28HH/A) pin K and ACSC2 connector (57HH/AB) pin 15K. - if there is no short circuit in the wiring replace the P2 RAM AIR IN ACTUATOR [28HH] ,
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - install the CONT-AIR COND SYSTEM 2 [57HH]
AMM 21-61-34-400-002. - connect the electrical connector (28HH/A) to the P2 RAM AIR IN ACTUATOR [28HH] .
I. If the fault continues:
(1) Swap the ACSC2 (57HH) and the ACSC1 (47HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
(a) If the fault moves with the ACSC2:
Subtask 21-61-00-810-189-D ** ON A/C NOT FOR ALL (1) Swap the ACSC2 (57HH) and the ACSC1 (47HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
(a) If the fault moves with the ACSC2:
- swap back the ACSC2 (57HH) and the ACSC1 (47HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002. - replace the CONT-AIR COND SYSTEM 2 [57HH]
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
- swap back the ACSC2 (57HH) and the ACSC1 (47HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
J. If the fault continues:
(1) Disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
Subtask 21-61-00-810-190-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (31HH/A) do a check for voltage between,
* pins E and F.
- replace the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH]
AMM 21-61-13-000-001 and,
AMM 21-61-13-400-001.
- disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (31HH/A) do a check for voltage again.
- replace the P2 RAM AIR IN ACTUATOR [28HH]
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - connect the electrical connector (31HH/A).
- connect the electrical connector (28HH/A),
- repeat para. 4.E.(1).(b) for,
* connector (30HH/A) and the VALVE-TURBINE BYPASS [30HH]
AMM 21-61-53-000-001 and,
AMM 21-61-53-400-001,
* connector (32HH/A) and the SENSOR-COMPRESSOR TEMPERATURE [32HH]
AMM 21-61-11-000-001 and,
AMM 21-61-11-400-001,
* connector (24HB/A) and the FLOW CTL UNIT - PACK 2 [24HB]
AMM 21-51-51-000-001 and,
AMM 21-51-51-400-001.
K. If the fault continues:
(1) disconnect the electrical connector (24HB1/A) from the SENSOR-PRESS, PACK 2 INLET [24HB1] .
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin C and ACSC2 connector (57HH/AA) pin 4A,
* connector (31HH/A) pin D and ACSC2 connector (57HH/AA) pin 4B.
(b) If there is a short circuit repair the related wiring between,
* connector (28HH/A) pin A and ACSC2 connector (57HH/AA) pin 14B,
* connector (28HH/A) pin B and ACSC2 connector (57HH/AA) pin 14A,
* connector (28HH/A) pin C and ACSC2 connector (57HH/AA) pin 14C:
Subtask 21-61-00-810-194-B ** ON A/C NOT FOR ALL (1) disconnect the electrical connector (24HB1/A) from the SENSOR-PRESS, PACK 2 INLET [24HB1] .
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (24HB1/A) do a check for 15VDC from ACSC primary channel between,
* pins A and C (+15VDC)
- replace the SENSOR-PRESS, PACK 2 INLET [24HB1]
AMM 21-51-13-000-001 and,
AMM 21-51-13-400-001. - connect the electrical connector (24HB1/A).
- Remove the CONT-AIR COND SYSTEM 2 [57HH]
AMM 21-61-34-000-002, - disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [31HH] ,
- at the electrical connector (31HH/A) do a check for a short circuit between,
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin C and ACSC2 connector (57HH/AA) pin 4A,
* connector (31HH/A) pin D and ACSC2 connector (57HH/AA) pin 4B.
- connect the electrical connector (31HH/A).
- disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR [28HH] ,
- at the electrical connector (28HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (28HH/A) pin A and ACSC2 connector (57HH/AA) pin 14B,
* connector (28HH/A) pin B and ACSC2 connector (57HH/AA) pin 14A,
* connector (28HH/A) pin C and ACSC2 connector (57HH/AA) pin 14C:
- connect the electrical connector (28HH/A).
L. If the fault continues:
(1) Disconnect the electrical connector (30HH/A) from the VALVE-TURBINE BYPASS [30HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (30HH/A) pin U and PC 2 connector (27HH/AA) pin 2A,
* connector (30HH/A) pin J and PC 2 connector (27HH/AA) pin 2B,
* connector (30HH/A) pin K and PC 2 connector (27HH/AA) pin 2C,
* connector (30HH/A) pin L and PC 2 connector (27HH/AA) pin 2D,
* connector (30HH/A) pin C and PC 2 connector (27HH/AA) pin 5B:
Subtask 21-61-00-810-192-A ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (30HH/A) from the VALVE-TURBINE BYPASS [30HH] ,
- at the electrical connector (30HH/A) do a check for a short circuit between,
* pins U and J, U and K, U and L, J and K, J and L, K and L,
* pins C and D and,
* GND and pins U, J, K, L and C.
(b) If there is a short circuit repair the related wiring between,
* connector (30HH/A) pin U and PC 2 connector (27HH/AA) pin 2A,
* connector (30HH/A) pin J and PC 2 connector (27HH/AA) pin 2B,
* connector (30HH/A) pin K and PC 2 connector (27HH/AA) pin 2C,
* connector (30HH/A) pin L and PC 2 connector (27HH/AA) pin 2D,
* connector (30HH/A) pin C and PC 2 connector (27HH/AA) pin 5B:
- connect the electrical connector (30HH/A).
M. If the fault continues:
(1) Disconnect the electrical connector (32HH/A),
(b) If there is a short circuit repair the related wiring between,
* connector (32HH/A) pin A and PC 2 connector (27HH/AA) pin 15A,
* connector (32HH/A) pin B and PC 2 connector (27HH/AA) pin 14D,
* connector (32HH/A) pin C and PC 2 connector (27HH/AA) pin 14C.
(b) If there is a short circuit repair the related wiring between,
* connector (7560VC) pin A and PC 2 connector (27HH/AB) pin 15C,
* connector (7560VC) pin B and PC 2 connector (27HH/AA) pin 10D,
* connector (7560VC) pin C and PC 2 connector (27HH/AA) pin 10C,
* connector (7560VC) pin D and PC 2 connector (27HH/AB) pin 15D.
(b) If there is a short circuit repair the related wiring between,
* connector (8HB/A) pin J and PC 2 connector (27HH/AA) pin 11C,
* connector (8HB/A) pin K and PC 2 connector (27HH/AA) pin 11B,
* connector (8HB/A) pin L and PC 2 connector (27HH/AA) pin 11A.
AMM 21-61-34-400-001.
(5) If the fault continues:
(a) Swap the SDAC's (1WV2 and 1WV1). (Ref. AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
Subtask 21-61-00-810-194-C ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (32HH/A),
- at the electrical connector (32HH/A) do a check for a short circuit between,
* pins A and B, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (32HH/A) pin A and PC 2 connector (27HH/AA) pin 15A,
* connector (32HH/A) pin B and PC 2 connector (27HH/AA) pin 14D,
* connector (32HH/A) pin C and PC 2 connector (27HH/AA) pin 14C.
- connect the electrical connector (32HH/A).
- disconnect the electrical connector (7560VC/A),
- at the electrical connector (7560VC) do a check for a short circuit between,
* pins A and B, A and C, A and D, B and C, B and D, C and D and,
* GND and pins A, B, C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (7560VC) pin A and PC 2 connector (27HH/AB) pin 15C,
* connector (7560VC) pin B and PC 2 connector (27HH/AA) pin 10D,
* connector (7560VC) pin C and PC 2 connector (27HH/AA) pin 10C,
* connector (7560VC) pin D and PC 2 connector (27HH/AB) pin 15D.
- connect the electrical connector (7560VC/A).
- disconnect the electrical connector (8HB/A) from the P2 FLOW CTL VALVE [8HB] .
- at the electrical connector (8HB/A) do a check for a short circuit between,
* pins J and K, J and L, K and L and,
* GND and pins J, K and L.
(b) If there is a short circuit repair the related wiring between,
* connector (8HB/A) pin J and PC 2 connector (27HH/AA) pin 11C,
* connector (8HB/A) pin K and PC 2 connector (27HH/AA) pin 11B,
* connector (8HB/A) pin L and PC 2 connector (27HH/AA) pin 11A.
- connect the electrical connector (8HB/A).
AMM 21-61-34-400-001.
(5) If the fault continues:
(a) Swap the SDAC's (1WV2 and 1WV1). (Ref. AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC2.
N. If the fault continues:
(1) Disconnect the electrical connector (30HH/A) from the VALVE-TURBINE BYPASS [30HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (30HH/A) pin U and ACSC2 connector (57HH/AB) pin 15D,
* connector (30HH/A) pin J and ACSC2 connector (57HH/AB) pin 15A,
* connector (30HH/A) pin K and ACSC2 connector (57HH/AB) pin 15B,
* connector (30HH/A) pin L and ACSC2 connector (57HH/AB) pin 15C,
* connector (30HH/A) pin C and ACSC2 connector (57HH/AB) pin 15E.
Subtask 21-61-00-810-192-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (30HH/A) from the VALVE-TURBINE BYPASS [30HH] ,
- at the electrical connector (30HH/A) do a check for a short circuit between,
* pins U and J, U and K, U and L, J and K, J and L, K and L, C and D and,
* GND and pins U, J, K, L and C.
(b) If there is a short circuit repair the related wiring between,
* connector (30HH/A) pin U and ACSC2 connector (57HH/AB) pin 15D,
* connector (30HH/A) pin J and ACSC2 connector (57HH/AB) pin 15A,
* connector (30HH/A) pin K and ACSC2 connector (57HH/AB) pin 15B,
* connector (30HH/A) pin L and ACSC2 connector (57HH/AB) pin 15C,
* connector (30HH/A) pin C and ACSC2 connector (57HH/AB) pin 15E.
- connect the electrical connector (30HH/A).
O. If the fault continues:
(1) Disconnect the electrical connector (32HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [32HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (32HH/A) pin B and ACSC2 connector (57HH/AA) pin 6B,
* connector (32HH/A) pin C and ACSC2 connector (57HH/AA) pin 6C,
* connector (32HH/A) pin D and ACSC2 connector (57HH/AA) pin 6A,
(b) If there is a short circuit repair the related wiring between,
* connector (24HB1/A) pin A and ACSC2 connector (57HH/AA) pin 10H,
* connector (24HB1/A) pin B and ACSC2 connector (57HH/AA) pin 10K,
* connector (24HB1/A) pin C and ACSC2 connector (57HH/AA) pin 10J.
AMM 21-61-34-400-002.
(4) If the fault continues:
(a) Swap the SDAC's (1WV2 and 1WV1). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
Subtask 21-61-00-710-091-A (1) Disconnect the electrical connector (32HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [32HH] ,
- at the electrical connector (32HH/A) do a check for a short circuit between,
* pins B and C, B and D, C and D and,
* GND and pins B, C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (32HH/A) pin B and ACSC2 connector (57HH/AA) pin 6B,
* connector (32HH/A) pin C and ACSC2 connector (57HH/AA) pin 6C,
* connector (32HH/A) pin D and ACSC2 connector (57HH/AA) pin 6A,
- connect the electrical connector (32HH/A).
- disconnect the electrical connector (24HB1/A),
- at the connector (24HB1/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (24HB1/A) pin A and ACSC2 connector (57HH/AA) pin 10H,
* connector (24HB1/A) pin B and ACSC2 connector (57HH/AA) pin 10K,
* connector (24HB1/A) pin C and ACSC2 connector (57HH/AA) pin 10J.
- connect the electrical connector (24HB1/A).
AMM 21-61-34-400-002.
(4) If the fault continues:
- replace the TEMP SENSOR RH MIXER [25HK]
AMM 21-63-16-000-001 and,
AMM 21-63-16-400-001.
(a) Swap the SDAC's (1WV2 and 1WV1). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC2.
P. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-61-00-860-070-A
A. Put the aircraft back to its initial configuration.
FCV Sensor Plate Inspection Area