Pack 1 Electrical Component with Short Circuit (AIR PACK 1 REGUL FAULT)
TASK 21-61-00-810-820-A
Pack 1 Electrical Component with Short Circuit (AIR PACK 1 REGUL FAULT)
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-865-050-A
Subtask 21-61-00-810-272-B ** ON A/C NOT FOR ALL
Subtask 21-61-00-860-069-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:54 UTC
Pack 1 Electrical Component with Short Circuit (AIR PACK 1 REGUL FAULT)
1. Possible Causes
- FLOW CTL UNIT - PACK 1 [23HB]
- P1 FLOW SENSOR [10HB]
- SENSOR-DELTA P, PACK 1 [23HB2]
- P1 RAM AIR IN ACTUATOR [8HH]
- P1 CONTROLLER [7HH]
- CONT-AIR COND SYSTEM 1 [47HH]
- SENSOR-WATER EXTRACTOR TEMPERATURE [11HH]
- VALVE-TURBINE BYPASS [10HH]
- SENSOR-COMPRESSOR TEMPERATURE [12HH]
- P1 FLOW CTL VALVE [11HB]
- P1 PRESS INL SENSOR [16HH]
- wiring
- SENSOR-PRESS, PACK 1 INLET [23HB1]
- SDAC
- TEMP SENSOR LH MIXER [24HK]
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WATER - SOAPY SOLUTION |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 12-33-21-618-001 | Pre-conditioning through the LP Ground Connection |
| ASM 215101 | |
| ASM 215102 | |
| AMM 21-51-11-000-001 | Removal of the Differential Pressure Sensor |
| AMM 21-51-11-400-001 | Installation of the Differential Pressure Sensor |
| AMM 21-51-13-000-001 | Removal of the Pack-Inlet Pressure Sensor |
| AMM 21-51-13-400-001 | Installation of the Pack-Inlet Pressure Sensor |
| AMM 21-51-51-000-001 | Removal of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-51-51-400-001 | Installation of the Pack Flow-Control Valve/ Pack Flow-Control Unit |
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
| AWM 216101 | |
| ASM 216102 | |
| AWM 216102 | |
| ASM 216103 | |
| AWM 216103 | |
| ASM 216104 | |
| AWM 216104 | |
| AWM 216109 | |
| AMM 21-61-11-000-001 | Removal of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-11-400-001 | Installation of the Compressor Outlet - Temperature Sensor |
| AMM 21-61-13-000-001 | Removal of the Water-Extractor Temperature Sensors |
| AMM 21-61-13-400-001 | Installation of the Water-Extractor Temperature Sensors |
| AMM 21-61-16-000-001 | Removal of the Pack-Inlet Pressure Sensor |
| AMM 21-61-16-400-002 | Installation of the Pack-Inlet Pressure Sensor |
| AMM 21-61-34-000-001 | Removal of the Pack Controller |
| AMM 21-61-34-000-002 | Removal of the Air-Conditioning System Controller |
| AMM 21-61-34-400-001 | Installation of the Pack Controller |
| AMM 21-61-34-400-002 | Installation of the Air-Conditioning System Controller |
| AMM 21-61-51-000-001 | Removal of the Air-Inlet Flap Actuator |
| AMM 21-61-51-400-001 | Installation of the Air-Inlet Flap Actuator 8HH and 28HH |
| AMM 21-61-53-000-001 | Removal of the Turbine Bypass Valve |
| AMM 21-61-53-400-001 | Installation of the Turbine Bypass Valve |
| AMM 21-63-16-000-001 | Removal of the Mixer Temperature Sensor |
| AMM 21-63-16-400-001 | Installation of the Mixer Temperature Sensor |
Subtask 21-61-00-865-050-A
A. Open this(these) circuit breaker(s):
Subtask 21-61-00-865-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
B. Close this(these) circuit breaker(s):
Subtask 21-61-00-710-088-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | AIR COND/PACK TEMP/CTL SYS1/1/115VAC | 1HH | X22 |
| 122VU | AIR COND/PACK TEMP CTL SYS2/1/115VAC | 2HH | Y18 |
C. Test
(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
Subtask 21-61-00-710-088-B ** ON A/C NOT FOR ALL (1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
NOTE: If the test finds a fault the PC gives a fault code for shop maintenance and also the related CFDS message(s) (refer to chapter 21-63-00 page block 301).
C. Test
(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
(2) Perform a leak check at the FCV Sensor plate:
(c) Apply a WATER - SOAPY SOLUTION to the connections behind the sensor plate to search for a leak.
4. Fault Isolation(1) Do a read out of the post flight report and do the operational test of the pack-temperature control system AMM 21-61-00-710-001.
(2) Perform a leak check at the FCV Sensor plate:
NOTE: This procedure is only applicable for FCV P/N 1806A0000-02, 1806A0000-02 Amdt A, 1806B0000-01, 1806B0000-01 Amdt A, 1806B0000-01 Amdt AB, 1806B0000-01 Amdt B and 1806B0000-02.
(a) On the AIR COND panel 30VU: - make sure that the PACK pushbutton switch is in the OFF position.
(c) Apply a WATER - SOAPY SOLUTION to the connections behind the sensor plate to search for a leak.
Subtask 21-61-00-810-272-B ** ON A/C NOT FOR ALL
A. If a leakage is found:
Subtask 21-61-00-810-112-A ** ON A/C NOT FOR ALL - replace the FLOW CTL UNIT - PACK 1 [23HB] , AMM 21-51-51-000-001 and AMM 21-51-51-400-001.
B. * If the post flight report gives the warning AIR PACK 1 REGUL FAULT without a maintenance message and,
* no AIR PACK 1 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
Subtask 21-61-00-810-181-B ** ON A/C NOT FOR ALL * no AIR PACK 1 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
- replace the P1 FLOW SENSOR [10HB] AMM 21-51-11-000-001 and AMM 21-51-11-400-001.
** If the post flight report gives the warning AIR PACK 1 REGUL FAULT and,
** the ECAM upper DU shows the warning AIR PACK 1 REGUL FAULT or,
*** If the post flight report gives the warning AIR PACK 1 REGUL FAULT with,
*** the maintenance message NO DATA FROM P1 CONT and,
*** the operational test of the pack-temperature control system gives the maintenance message NO TEST RECEPTION FROM P1 CONT: - do the work steps which follow.
NOTE: Additional Information
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216102,
ASM 216104 and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
For wiring and pin identification used in this procedure:
ASM 215101,
ASM 216102,
ASM 216104 and,
AWM 216109.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
C. Check for short circuit at the P1 RAM AIR IN ACTUATOR [8HH] 115VAC supply lines
(1) Remove the P1 CONTROLLER [7HH] ,
AMM 21-61-34-000-001:
(2) Disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] :
Subtask 21-61-00-810-182-A ** ON A/C NOT FOR ALL (1) Remove the P1 CONTROLLER [7HH] ,
AMM 21-61-34-000-001:
(2) Disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] :
- do a check for a short circuit between,
* pins J and N and,
* GND and pins J and N. - if there is a short circuit repair the related wiring between,
* connector (8HH/A) pin J and PC connector (7HH/AB) pin 15A,
* connector (8HH/A) pin N and PC connector (7HH/AB) pin 14B. - if there is no short circuit in the wiring replace the P1 RAM AIR IN ACTUATOR [8HH] ,
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - install the P1 CONTROLLER [7HH]
AMM 21-61-34-400-001. - connect the electrical connector (8HH/A) to the P1 RAM AIR IN ACTUATOR [8HH] .
D. If the fault continues:
(1) Swap the PC 1 (7HH) and the PC 2 (27HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
(a) If the fault moves with the PC 1:
Subtask 21-61-00-810-183-B ** ON A/C NOT FOR ALL (1) Swap the PC 1 (7HH) and the PC 2 (27HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
(a) If the fault moves with the PC 1:
- swap back the PC 1 (7HH) and the PC 2 (27HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001. - replace the P1 CONTROLLER [7HH]
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
- swap back the PC 1 (7HH) and the PC 2 (27HH)
AMM 21-61-34-000-001 and,
AMM 21-61-34-400-001.
E. If the fault continues:
(1) Disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
Subtask 21-61-00-810-184-A ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (11HH/A) do a check for voltage between,
* pins E and F.
- replace the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH]
AMM 21-61-13-000-001 and,
AMM 21-61-13-400-001.
- disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (11HH/A) do a check for voltage again.
- replace the P1 RAM AIR IN ACTUATOR [8HH]
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - connect the electrical connector (11HH/A).
- connect the electrical connector (8HH/A),
- repeat para. 4.E.(1).(b) for,
* connector (10HH/A) and the VALVE-TURBINE BYPASS [10HH]
AMM 21-61-53-000-001 and,
AMM 21-61-53-400-001,
* connector (12HH/A) and the SENSOR-COMPRESSOR TEMPERATURE [12HH]
AMM 21-61-11-000-001 and,
AMM 21-61-11-400-001,
* connector (11HB/A) and the P1 FLOW CTL VALVE [11HB]
AMM 21-51-51-000-001 and,
AMM 21-51-51-400-001.
F. If the fault continues:
(1) disconnect the electrical connector (7559VC/A) from the P1 PRESS INL SENSOR [16HH] .
(b) If there is a short circuit repair the related wiring between,
* connector (11HH/A) pin E and PC 1 connector (7HH/AA) pin 14A,
* connector (11HH/A) pin F and PC 1 connector (7HH/AA) pin 14B.
(b) If there is a short circuit repair the related wiring between,
* connector (8HH/A) pin A and PC 1 connector (7HH/AA) pin 11D,
* connector (8HH/A) pin B and PC 1 connector (7HH/AA) pin 12A,
* connector (8HH/A) pin C and PC 1 connector (7HH/AA) pin 12B:
Subtask 21-61-00-810-112-B ** ON A/C NOT FOR ALL (1) disconnect the electrical connector (7559VC/A) from the P1 PRESS INL SENSOR [16HH] .
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (7559VC) do a check for 15VDC from pack controller primary channel between,
* pins A and C (+15VDC) and,
* D and C (-15VDC).
- replace the P1 PRESS INL SENSOR [16HH]
AMM 21-61-16-000-001 and,
AMM 21-61-16-400-002. - connect the electrical connector (7559VC/A).
- Remove the P1 CONTROLLER [7HH]
AMM 21-61-34-000-001, - disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
- at the electrical connector (11HH/A) do a check for a short circuit between,
* pins E and F and,
* GND and pins E and F.
(b) If there is a short circuit repair the related wiring between,
* connector (11HH/A) pin E and PC 1 connector (7HH/AA) pin 14A,
* connector (11HH/A) pin F and PC 1 connector (7HH/AA) pin 14B.
- connect the electrical connector (11HH/A).
- disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] ,
- at the electrical connector (8HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (8HH/A) pin A and PC 1 connector (7HH/AA) pin 11D,
* connector (8HH/A) pin B and PC 1 connector (7HH/AA) pin 12A,
* connector (8HH/A) pin C and PC 1 connector (7HH/AA) pin 12B:
- connect the electrical connector (8HH/A).
G. * If the post flight report gives the warning AIR PACK 1 REGUL FAULT without a maintenance message and,
* no AIR PACK 1 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
Subtask 21-61-00-810-181-C ** ON A/C NOT FOR ALL * no AIR PACK 1 REGUL FAULT warning shows on the ECAM upper DU and,
* no maintenance message shows:
- replace the SENSOR-DELTA P, PACK 1 [23HB2] ,
AMM 21-51-11-000-001 and AMM 21-51-11-400-001 (less probable cause for this failure).
- replace the FLOW CTL UNIT - PACK 1 [23HB] ,
AMM 21-51-51-000-001 and AMM 21-51-51-400-001. - no further action is necessary.
** If the post flight report gives the warning AIR PACK 1 REGUL FAULT and,
** the ECAM upper DU shows the warning AIR PACK 1 REGUL FAULT or: - do the work steps which follow.
NOTE: Additional Information
For wiring and pin identification used in this procedure:
ASM 215102,
ASM 216103,
ASM 216104,
AWM 216101,
AWM 216102,
AWM 216103and,
AWM 216104.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
For wiring and pin identification used in this procedure:
ASM 215102,
ASM 216103,
ASM 216104,
AWM 216101,
AWM 216102,
AWM 216103and,
AWM 216104.
For disconnection/reconnection of electrical connectors refer to the applicable work step AMM TASK reference in the applicable paras. 4. B, C, D and E.
H. Check for short circuit at the P1 RAM AIR IN ACTUATOR [8HH] 115VAC supply lines
(1) Remove the CONT-AIR COND SYSTEM 1 [47HH] ,
AMM 21-61-34-000-002:
(2) Disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] :
Subtask 21-61-00-810-182-B ** ON A/C NOT FOR ALL (1) Remove the CONT-AIR COND SYSTEM 1 [47HH] ,
AMM 21-61-34-000-002:
(2) Disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] :
- do a check for a short circuit between,
* pins J and K and,
* GND and pins J and K. - if there is a short circuit repair the related wiring between,
* connector (8HH/A) pin J and ACSC1 connector (47HH/AB) pin 15J,
* connector (8HH/A) pin K and ACSC1 connector (47HH/AB) pin 15K. - if there is no short circuit in the wiring replace the P1 RAM AIR IN ACTUATOR [8HH] ,
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - install the CONT-AIR COND SYSTEM 1 [47HH]
AMM 21-61-34-400-002. - connect the electrical connector (8HH/A) to the P1 RAM AIR IN ACTUATOR [8HH] .
I. If the fault continues:
(1) Swap the ACSC1 (47HH) and the ACSC2 (57HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
(a) If the fault moves with the ACSC1:
Subtask 21-61-00-810-183-D ** ON A/C NOT FOR ALL (1) Swap the ACSC1 (47HH) and the ACSC2 (57HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
(a) If the fault moves with the ACSC1:
- swap back the ACSC1 (47HH) and the ACSC2 (57HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002. - replace the CONT-AIR COND SYSTEM 1 [47HH]
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
- swap back the ACSC1 (47HH) and the ACSC2 (57HH)
AMM 21-61-34-000-002 and,
AMM 21-61-34-400-002.
J. If the fault continues:
(1) Disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
Subtask 21-61-00-810-184-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (11HH/A) do a check for voltage between,
* pins E and F.
- replace the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH]
AMM 21-61-13-000-001 and,
AMM 21-61-13-400-001.
- disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] ,
- make sure that the electrical connector is clean and in the correct condition,
- at the electrical connector (11HH/A) do a check for voltage again.
- replace the P1 RAM AIR IN ACTUATOR [8HH]
AMM 21-61-51-000-001 and,
AMM 21-61-51-400-001. - connect the electrical connector (11HH/A).
- connect the electrical connector (8HH/A),
- repeat para. 4.E.(1).(b) for,
* connector (10HH/A) and the VALVE-TURBINE BYPASS [10HH]
AMM 21-61-53-000-001 and,
AMM 21-61-53-400-001,
* connector (12HH/A) and the SENSOR-COMPRESSOR TEMPERATURE [12HH]
AMM 21-61-11-000-001 and,
AMM 21-61-11-400-001,
* connector (23HB/A) and the FLOW CTL UNIT - PACK 1 [23HB]
AMM 21-51-51-000-001 and,
AMM 21-51-51-400-001.
K. If the fault continues:
(1) disconnect the electrical connector (23HB1/A) from the SENSOR-PRESS, PACK 1 INLET [23HB1] .
(b) If there is a short circuit repair the related wiring between,
* connector (11HH/A) pin C and ACSC1 connector (47HH/AA) pin 4A,
* connector (11HH/A) pin D and ACSC1 connector (47HH/AA) pin 4B.
(b) If there is a short circuit repair the related wiring between,
* connector (8HH/A) pin A and ACSC1 connector (47HH/AA) pin 14B,
* connector (8HH/A) pin B and ACSC1 connector (47HH/AA) pin 14A,
* connector (8HH/A) pin C and ACSC1 connector (47HH/AA) pin 14C:
Subtask 21-61-00-810-193-B ** ON A/C NOT FOR ALL (1) disconnect the electrical connector (23HB1/A) from the SENSOR-PRESS, PACK 1 INLET [23HB1] .
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (23HB1/A) do a check for 15VDC from ACSC primary channel between,
* pins A and C (+15VDC)
- replace the SENSOR-PRESS, PACK 1 INLET [23HB1]
AMM 21-51-13-000-001 and,
AMM 21-51-13-400-001. - connect the electrical connector (23HB1/A).
- Remove the CONT-AIR COND SYSTEM 1 [47HH]
AMM 21-61-34-000-002, - disconnect the electrical connector (11HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE [11HH] ,
- at the electrical connector (11HH/A) do a check for a short circuit between,
* pins C and D and,
* GND and pins C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (11HH/A) pin C and ACSC1 connector (47HH/AA) pin 4A,
* connector (11HH/A) pin D and ACSC1 connector (47HH/AA) pin 4B.
- connect the electrical connector (11HH/A).
- disconnect the electrical connector (8HH/A) from the P1 RAM AIR IN ACTUATOR [8HH] ,
- at the electrical connector (8HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (8HH/A) pin A and ACSC1 connector (47HH/AA) pin 14B,
* connector (8HH/A) pin B and ACSC1 connector (47HH/AA) pin 14A,
* connector (8HH/A) pin C and ACSC1 connector (47HH/AA) pin 14C:
- connect the electrical connector (8HH/A).
L. If the fault continues:
(1) Disconnect the electrical connector (10HH/A) from the VALVE-TURBINE BYPASS [10HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (10HH/A) pin U and PC 1 connector (7HH/AA) pin 2A,
* connector (10HH/A) pin J and PC 1 connector (7HH/AA) pin 2B,
* connector (10HH/A) pin K and PC 1 connector (7HH/AA) pin 2C,
* connector (10HH/A) pin L and PC 1 connector (7HH/AA) pin 2D,
* connector (10HH/A) pin C and PC 1 connector (7HH/AB) pin 5B.
Subtask 21-61-00-810-186-A ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (10HH/A) from the VALVE-TURBINE BYPASS [10HH] ,
- at the electrical connector (10HH/A) do a check for a short circuit between,
* pins U and J, U and K, U and L, J and K, J and L, K and L, C and D and,
* GND and pins U, J, K, L and C.
(b) If there is a short circuit repair the related wiring between,
* connector (10HH/A) pin U and PC 1 connector (7HH/AA) pin 2A,
* connector (10HH/A) pin J and PC 1 connector (7HH/AA) pin 2B,
* connector (10HH/A) pin K and PC 1 connector (7HH/AA) pin 2C,
* connector (10HH/A) pin L and PC 1 connector (7HH/AA) pin 2D,
* connector (10HH/A) pin C and PC 1 connector (7HH/AB) pin 5B.
- connect the electrical connector (10HH/A).
M. If the fault continues:
(1) Disconnect the electrical connector (12HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [12HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (12HH/A) pin A and PC 1 connector (7HH/AA) pin 15A,
* connector (12HH/A) pin B and PC 1 connector (7HH/AA) pin 14D,
* connector (12HH/A) pin C and PC 1 connector (7HH/AA) pin 14C.
(b) If there is a short circuit repair the related wiring between,
* connector (7559VC) pin A and PC 1 connector (7HH/AB) pin 15C,
* connector (7559VC) pin D and PC 1 connector (7HH/AB) pin 15D,
* connector (7559VC) pin C and PC 1 connector (7HH/AA) pin 10C,
* connector (7559VC) pin B and PC 1 connector (7HH/AA) pin 10D.
(b) If there is a short circuit repair the related wiring between,
* connector (11HB/A) pin J and PC 1 connector (7HH/AA) pin 11C,
* connector (11HB/A) pin K and PC 1 connector (7HH/AA) pin 11B,
* connector (11HB/A) pin L and PC 1 connector (7HH/AA) pin 11A.
AMM 21-61-34-400-001.
(5) If the fault continues:
(a) Swap the SDAC's (1WV1 and 1WV2). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
Subtask 21-61-00-810-193-C ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (12HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [12HH] ,
- at the electrical connector (12HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (12HH/A) pin A and PC 1 connector (7HH/AA) pin 15A,
* connector (12HH/A) pin B and PC 1 connector (7HH/AA) pin 14D,
* connector (12HH/A) pin C and PC 1 connector (7HH/AA) pin 14C.
- connect the electrical connector (12HH/A).
- disconnect the electrical connector (7559VC/A),
- at the connector (7559VC) do a check for a short circuit between,
* pins A and B, A and C, A and D, B and C, B and D, C and D and,
* GND and pins A, B, C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (7559VC) pin A and PC 1 connector (7HH/AB) pin 15C,
* connector (7559VC) pin D and PC 1 connector (7HH/AB) pin 15D,
* connector (7559VC) pin C and PC 1 connector (7HH/AA) pin 10C,
* connector (7559VC) pin B and PC 1 connector (7HH/AA) pin 10D.
- connect the electrical connector (7559VC/A).
- disconnect the electrical connector (11HB/A) from the P1 FLOW CTL VALVE [11HB] ,
- at the electrical connector (11HB/A) do a check for a short circuit between,
* pins J and K, J and L, K and L and,
* GND and pins J, K and L.
(b) If there is a short circuit repair the related wiring between,
* connector (11HB/A) pin J and PC 1 connector (7HH/AA) pin 11C,
* connector (11HB/A) pin K and PC 1 connector (7HH/AA) pin 11B,
* connector (11HB/A) pin L and PC 1 connector (7HH/AA) pin 11A.
- connect the electrical connector (11HB/A).
AMM 21-61-34-400-001.
(5) If the fault continues:
(a) Swap the SDAC's (1WV1 and 1WV2). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC1.
N. If the fault continues:
(1) Disconnect the electrical connector (10HH/A) from the VALVE-TURBINE BYPASS [10HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (10HH/A) pin U and ACSC1 connector (47HH/AA) pin 15D,
* connector (10HH/A) pin J and ACSC1 connector (47HH/AA) pin 15A,
* connector (10HH/A) pin K and ACSC1 connector (47HH/AA) pin 15B,
* connector (10HH/A) pin L and ACSC1 connector (47HH/AA) pin 15C,
* connector (10HH/A) pin C and ACSC1 connector (47HH/AB) pin 15E.
Subtask 21-61-00-810-186-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (10HH/A) from the VALVE-TURBINE BYPASS [10HH] ,
- at the electrical connector (10HH/A) do a check for a short circuit between,
* pins U and J, U and K, U and L, J and K, J and L, K and L, C and D and,
* GND and pins U, J, K, L and C.
(b) If there is a short circuit repair the related wiring between,
* connector (10HH/A) pin U and ACSC1 connector (47HH/AA) pin 15D,
* connector (10HH/A) pin J and ACSC1 connector (47HH/AA) pin 15A,
* connector (10HH/A) pin K and ACSC1 connector (47HH/AA) pin 15B,
* connector (10HH/A) pin L and ACSC1 connector (47HH/AA) pin 15C,
* connector (10HH/A) pin C and ACSC1 connector (47HH/AB) pin 15E.
- connect the electrical connector (10HH/A).
O. If the fault continues:
(1) Disconnect the electrical connector (12HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [12HH] ,
(b) If there is a short circuit repair the related wiring between,
* connector (12HH/A) pin B and ACSC1 connector (47HH/AA) pin 6B,
* connector (12HH/A) pin C and ACSC1 connector (47HH/AA) pin 6C,
* connector (12HH/A) pin D and ACSC1 connector (47HH/AA) pin 6A,
(b) If there is a short circuit repair the related wiring between,
* connector (23HB1/A) pin A and ACSC1 connector (47HH/AB) pin 10H,
* connector (23HB1/A) pin B and ACSC1 connector (47HH/AB) pin 10K,
* connector (23HB1/A) pin C and ACSC1 connector (47HH/AA) pin 10J.
AMM 21-61-34-400-002.
(4) If the fault continues:
(a) Swap the SDAC's (1WV1 and 1WV2). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
Subtask 21-61-00-710-089-A (1) Disconnect the electrical connector (12HH/A) from the SENSOR-COMPRESSOR TEMPERATURE [12HH] ,
- at the electrical connector (12HH/A) do a check for a short circuit between,
* pins B and C, B and D, C and D and,
* GND and pins B, C and D.
(b) If there is a short circuit repair the related wiring between,
* connector (12HH/A) pin B and ACSC1 connector (47HH/AA) pin 6B,
* connector (12HH/A) pin C and ACSC1 connector (47HH/AA) pin 6C,
* connector (12HH/A) pin D and ACSC1 connector (47HH/AA) pin 6A,
- connect the electrical connector (12HH/A).
- disconnect the electrical connector (23HB1/A),
- at the connector (23HB1/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(b) If there is a short circuit repair the related wiring between,
* connector (23HB1/A) pin A and ACSC1 connector (47HH/AB) pin 10H,
* connector (23HB1/A) pin B and ACSC1 connector (47HH/AB) pin 10K,
* connector (23HB1/A) pin C and ACSC1 connector (47HH/AA) pin 10J.
- connect the electrical connector (23HB1/A).
AMM 21-61-34-400-002.
(4) If the fault continues:
- replace the TEMP SENSOR LH MIXER [24HK]
AMM 21-63-16-000-001 and,
AMM 21-63-16-400-001.
(a) Swap the SDAC's (1WV1 and 1WV2). (Ref.AMM TASK 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC1.
P. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-61-00-860-069-A
A. Put the aircraft back to its initial configuration.
FCV Sensor Plate Inspection Area