Pack 2 Anti Ice Valve Fault


TASK 21-61-00-810-819-A
Pack 2 Anti Ice Valve Fault


1. Possible Causes
  • P2 CONTROLLER [27HH]
  • VALVE-ANTI ICE [37HH]
  • wiring
  • [57HH]
  • SOLENOID VALVE (40HH)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
ASM 216102
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-000-002
Removal of the Air-Conditioning System Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
AMM 21-61-34-400-002
Installation of the Air-Conditioning System Controller
AMM 21-61-41-000-001
Removal of the Anti-Ice Valve
AMM 21-61-41-000-003
Removal of the Solenoid Valve
AMM 21-61-41-400-001
Installation of the Anti-Ice Valve
AMM 21-61-41-400-003
Installation of the Solenoid Valve
3. Fault Confirmation
Subtask 21-61-00-710-086-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
4. Fault Isolation
Subtask 21-61-00-810-105-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 CONT OR ANTI ICE VALVE:
   (1) If the fault moves with the PC 2:
   (2) If the fault does not move with the PC 2:
   (3) If the fault continues:
  • do a check and repair the wiring ASM 216102 from:
  • the VALVE (37HH)A pin A and the PC 2 (27HH)AB pin 8A and,
  • the VALVE (37HH)A pins B and C to ground.
Subtask 21-61-00-810-105-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 ANTI ICE VALVE(37HH):
   (1) If the fault moves with the ACSC2:
  • swap back the ACSC2 (57HH) and the ACSC1 (47HH) and,
  • replace the [57HH] .
   (2) If the fault does not move with the ACSC2:
   (3) If the fault continues:
  • do a check and repair the wiring ASM 216102 from:
  • the VALVE (37HH) to the ACSC2 (57HH) and,
  • the VALVE (37HH) to ground.
Subtask 21-61-00-810-105-D ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message P2 CONT OR ANTI ICE VALVE:
   (1) If the fault moves with the PC 2:
   (2) If the fault does not move with the PC 2:
   (3) If the fault continues:
  • do a check and repair the wiring ASM 216102 from:
  • the VALVE (37HH)A pin A and the PC 2 (27HH)AB pin 8A and,
  • the VALVE (37HH)A pins B and C to ground.
   (4) If the fault continues:
   (5) If the fault continues:
  • do a check and repair the wiring ASM 216102 from:
  • the SOLENOID VALVE (40HH)A pin A and the PC 2 (27HH)AB pin 8A and,
  • the SOLENOID VALVE (40HH)A pins B and C to ground.
Subtask 21-61-00-710-087-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-61-00-860-068-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.