W DOC AIRBUS | TSM A320F

Pack 1 Air Inlet Flap Actuator Fault


TASK 21-61-00-810-812-A
Pack 1 Air Inlet Flap Actuator Fault


CAUTION: DO NOT SWAP THE PACK/ACS CONTROLLERS. THIS CAN CAUSE DAMAGE TO THEM IF THERE IS AN ELECTRICAL FAULT IN THE ACTUATOR.
1. Possible Causes
  • P1 RAM AIR IN ACTUATOR [8HH]
  • wiring
  • P1 CONTROLLER [7HH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-61-00-710-001
Operational Test of the Pack Temperature-Control System
ASM 216104
AMM 21-61-34-000-001
Removal of the Pack Controller
AMM 21-61-34-400-001
Installation of the Pack Controller
AMM 21-61-51-000-001
Removal of the Air-Inlet Flap Actuator
AMM 21-61-51-400-001
Installation of the Air-Inlet Flap Actuator 8HH and 28HH
3. Fault Confirmation
Subtask 21-61-00-710-072-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
NOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
Subtask 21-61-00-710-072-B ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
4. Fault Isolation
Subtask 21-61-00-810-086-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P1 RAM AIR IN ACTUATOR:
Subtask 21-61-00-810-086-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P1 RAM AIR IN ACTUATOR(8HH):
Subtask 21-61-00-810-138-A
B. If the pack 1 ram-air inlet-actuator does not operate correctly on the ground with the pushbutton switch PACK 1, which is installed on the panel 30VU, in the OFF position:
Subtask 21-61-00-810-087-A ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message P1 RAM AIR IN ACTUATOR:
   (1) If the fault continues:
  • do a check and repair the wiring ASM 216104 from:
  • the ACTUATOR (8HH) to the PC 1 (7HH) and,
  • the ACTUATOR (8HH) to ground.
   (2) If the fault continues:
Subtask 21-61-00-810-087-B ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message P1 RAM AIR IN ACTUATOR(8HH):
   (1) If the fault continues:
  • do a check and repair the wiring ASM 216104 from:
  • the ACTUATOR (8HH) to the ACSC1 (47HH) and,
  • the ACTUATOR (8HH) to ground.
Subtask 21-61-00-710-073-A
D. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 21-61-00-860-061-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:24:53 UTC