Pack 2 is incorrectly off
TASK 21-61-00-810-809-A
Pack 2 is incorrectly off
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 21-61-00-710-066-A ** ON A/C NOT FOR ALL
Subtask 21-61-00-810-079-A
Subtask 21-61-00-860-058-A
[Rev.8 from Aug 2018]
2026.04.04 04:24:52 UTC
Pack 2 is incorrectly off
1. Possible Causes
- P/BSW-AIR COND/PACK 2 [6HB]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-61-00-710-001 | Operational Test of the Pack Temperature-Control System |
Subtask 21-61-00-710-066-A ** ON A/C NOT FOR ALL
A. Do the operational test of the pack temperature-control system AMM 21-61-00-710-001.
Subtask 21-61-00-710-066-B ** ON A/C NOT FOR ALL 4. Fault IsolationNOTE: If a fault is detected, the PC gives a fault code for shop maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
Subtask 21-61-00-810-079-A
A. If the ECAM upper DU gives the warning AIR PACK 2 OFF, but no maintenance message comes on:
Subtask 21-61-00-710-067-A - make sure that the P/BSW-AIR COND/PACK 2 [6HB] (pushbutton switch PACK 2), which is installed on the panel 30VU, is in the on position (with the FAULT and OFF legends off).
B. Do the test as given in the Para. 3.A.
5. Close-upSubtask 21-61-00-860-058-A
A. Put the aircraft back to its initial configuration.