TASK 21-58-00-810-824-A
System Latched by Ecam Warning
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-58-00-710-093-A ** ON A/C NOT FOR ALL
Subtask 21-58-00-810-095-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:51 UTC
System Latched by Ecam Warning
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-58-00-710-001 | Operational Test of the Conditioned Service Air System without Bleed Air |
| AMM 21-58-00-710-002 | Operational Test of the Conditioned Service Air System with Bleed Air |
Subtask 21-58-00-710-093-A ** ON A/C NOT FOR ALL
A. Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
4. Fault IsolationSubtask 21-58-00-810-095-A ** ON A/C NOT FOR ALL
A. If the system test without bleed gives a maintenance message, do the related trouble shooting procedure.
Subtask 21-58-00-810-096-A ** ON A/C NOT FOR ALL B. If the system test without bleed gives the message TEST OK (SYSTEM STILL LATCHED - TEST WITH BLEED NEEDED):
Subtask 21-58-00-710-094-A ** ON A/C NOT FOR ALL - do the operational test of the conditioned service air system with bleed air AMM 21-58-00-710-002.
C. Do the test as given in the Para. 3.A.