Failure of the CFDIU Detected by the CSAS
TASK 21-58-00-810-812-A
Failure of the CFDIU Detected by the CSAS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 21-58-00-710-072-A ** ON A/C NOT FOR ALL
Subtask 21-58-00-810-061-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:24:50 UTC
Failure of the CFDIU Detected by the CSAS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 21-58-34-000-001 | Removal of the CSAS Control Unit |
| AMM 21-58-34-400-001 | Installation of the CSAS Control Unit |
| AMM 31-32-00-740-002 | BITE Test of the Centralized Fault Display Interface Unit (CFDIU) |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| ASM 462105 |
Subtask 21-58-00-710-072-A ** ON A/C NOT FOR ALL
A. Do a read out of the post flight report.
4. Fault IsolationNOTE: The fault cannot be reproduced on the ground.
Subtask 21-58-00-810-061-A ** ON A/C NOT FOR ALL
A. If the post flight report gives the maintenance message CFDIU(1TW)/CSAS CTL UNIT (100HW):
(2) If the fault continues:
Subtask 21-58-00-710-073-A ** ON A/C NOT FOR ALL - do the BITE test of the CFDIU AMM 31-32-00-740-002.
(2) If the fault continues:
- replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the CSAS CONTROL UNIT [100HW] AMM 21-58-34-000-001 and AMM 21-58-34-400-001.
- remove the CFDIU and the CSAS Control Unit
- do a check and repair the wiring of the CFDIU DATA BUS : between pins AA/11F,11G of the CFDIU and pins AB/11E,11F of the CSAS CONTROL UNIT ASM 462105
- install the CFDIU and the CSAS CONTROL UNIT.
B. Do the test as given in the Para. 3.A.