W DOC AIRBUS | TSM A320F

Pin Program Disagree Fault


TASK 21-58-00-810-808-A
Pin Program Disagree Fault


1. Possible Causes
  • wiring
  • CSAS CONTROL UNIT [100HW]
  • IGGS CTL UNIT [1YA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215301
AMM 21-58-00-710-001
Operational Test of the Conditioned Service Air System without Bleed Air
AMM 21-58-34-000-001
Removal of the CSAS Control Unit
AMM 21-58-34-400-001
Installation of the CSAS Control Unit
ASM 471101
AMM 47-31-34-000-001
Removal of the IGGS Controller Unit
AMM 47-31-34-400-001
Installation of the IGGS Controller Unit
3. Fault Confirmation
Subtask 21-58-00-710-064-A ** ON A/C NOT FOR ALL
A. Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
Subtask 21-58-00-860-050-A ** ON A/C NOT FOR ALL
B. Do a read out of the CSAS / IGGS specific data page on the MCDU
ACTION
RESULT
1.On the AIR COND menu page:
On the MCDU:
  • push the line key adjacent to the CSAS indication.
  • the CSAS/IGGS menu page comes on.
2.On the CSAS/IGGS menu page:
  • push the line key adjacent to the SPECIFIC DATA indication.
  • the CSAS/IGGS SPECIFIC DATA page comes on.
  • the CSAS column shows PIN SA.
  • the IGGS column shows PIN SA.
4. Fault Isolation
Subtask 21-58-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PIN PROG DISAGREE and the CSAS column on the SPECIFIC DATA page shows PIN A330 or PIN A3423 or PIN A3456:
  • do a check and repair the wiring from:
  • the CSAS CONTROL UNIT (100HW) pin program AK5 to ground,
  • the CSAS CONTROL UNIT (100HW) pin program AK6 to open circuit,
  • the CSAS CONTROL UNIT (100HW) pin program AK7 to ground,
  • the CSAS CONTROL UNIT (100HW) pin program AK8 to open circuit ASM 215301.
   (1) If the fault continues:
Subtask 21-58-00-810-072-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message PIN PROG DISAGREE and the IGGS column on the SPECIFIC DATA page shows PIN A330 or PIN A3423 or PIN A3456:
  • do a check and repair the wiring from:
  • the IGGS CONTROL UNIT (1YA) pin program A/73 to pin A/40,
  • the IGGS CONTROL UNIT (1YA) pin program A/62 to open circuit,
  • the IGGS CONTROL UNIT (1YA) pin program A/85 to pin A/40,
  • the IGGS CONTROL UNIT (1YA) pin program A/74 to pin A/40,
  • the IGGS CONTROL UNIT (1YA) pin program A/63 to pin A/40 ASM 471101.
   (1) If the fault continues:
Subtask 21-58-00-710-065-A ** ON A/C NOT FOR ALL
C. Do the test as given in the Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:24:50 UTC