Failure of the CSAS Detected by the IGGS


TASK 21-58-00-810-807-A
Failure of the CSAS Detected by the IGGS


1. Possible Causes
  • CSAS CONTROL UNIT [100HW]
  • IGGS CTL UNIT [1YA]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 215301
AMM 21-58-00-710-001
Operational Test of the Conditioned Service Air System without Bleed Air
AMM 21-58-34-000-001
Removal of the CSAS Control Unit
AMM 21-58-34-400-001
Installation of the CSAS Control Unit
AMM 47-31-34-000-001
Removal of the IGGS Controller Unit
AMM 47-31-34-400-001
Installation of the IGGS Controller Unit
3. Fault Confirmation
Subtask 21-58-00-710-062-A ** ON A/C NOT FOR ALL
A. Do the operational test of the conditioned service air system without bleed air AMM 21-58-00-710-001.
4. Fault Isolation
Subtask 21-58-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CSAS CTL UNIT (100HW)/IGGS CTL UNIT (1YA):
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from:
  • the CSAS CONTROL UNIT (100HW) to the IGGS CONTROL UNIT (1YA) ASM 215301.
Subtask 21-58-00-710-063-A ** ON A/C NOT FOR ALL
B. Do the test as given in the Para. 3.A.